ADJUSTING THE WATER PRESSURE
To carry out this operation, proceed as follows.
1) Undo the screws to remove the side panel (A).
2) Turn on the water supply tap (B).
3) Unscrew the ring nut (C).
4) Turn the cooking chamber water intake screw (D) to bring the pressure reading on the pres-
sure gauge (E) to 1 bar.
If the water pressure is too low, install a device to increase the pressure.
5) Retighten the ring nut (C).
6) Replace the panel (A) and screw the screws back into place.
7) Turn the water supply tap (B) back off when the operation is complete.
INSTRUCTIONS AND WARNINGS FOR REPLACING PARTS
GB
Important
Before carrying out any replacement procedure, activate all the safety devices provided
and decide whether staff at work and those in the vicinity should be informed. In
particular, turn off the gas and water supply taps, cut off the electricity supply to the
appliance using the master switch and prevent access to all devices which might cause
unexpected health and safety hazards if turned on.
If worn parts have to be replaced, use original spare parts only.
The manufacturer declines all responsibly for injury or damage to components due to the
use of non original parts, or extraordinary work on the appliance which may modify the
safety requirements without the manufacturer's authorisation.
When ordering components, follow the instructions provided in the parts catalogue.
Caution - Warning
Replacement operations must be carried out by authorised, qualifi ed staff , in accordance
with the relevant legal requirements.
3338970_GB_inst
E
C
D
REPLACING PARTS
A
- 14 -
B
ENGLISH