TROUBLESHOOTING
The appliance has been tested before being put into service.
The information provided below is intended to assist in the identifi cation and correction of any
anomalies and malfunctions which might occur during use.
The user can solve some of these problems himself, but for others specifi c technical knowledge
or skill is required, and so they must only be carried out by qualifi ed staff with recognised
experience acquired in the specifi c sector of operation.
Important
For all requirements contact the agents or the headquarters of Angelo Po which can be
found in the contacts section of the website http://www.angelopo.com.
Fault
The appliance does not
switch on
Smell of gas
Cooking cycle does not start
or stops suddenly
The burner does not light or
goes out suddenly
Burner does not light or goes
out suddenly with "E12"
alarm signalled
TABLE OF ALARM INDICATIONS
If the problem or fault noticed is not amongst those
listed in the table, consult the "Key to Alarms" table
provided below.
The information provided below s intended to
identify the alarm signals which appear on the
display (11).
Important
Press button (14) to reset the alarm and the
cooking cycle restarts automatically; if this is not
the case, press the start key (2).
3338970_ut_GB
FAULT
Cause
Fuse "blown"
Safety or protection device (safe-
ty thermostat or overload cutout)
tripped.
Electronic circuit board damaged
Gas leaks in supply system
Control board electronic circuit
board damaged
Alarm triggered
Gas valve faulty
Air intake in base obstructed
Ignition plug wires disconnected
or damaged
Ignition plugs dirty or damaged
Ignition monitoring device faulty
11
14
- 19 -
Remedy
Replace the fuse (see "installation
manual").
Press device reset button.
Contact the after-sales service.
Check the tightness of the system
Contact the after-sales service
Consult the "Key to Alarms" table
Replace gas valve
Clean the air intake
Reconnect or replace the wires
Clean or replace the plugs
Replace the device