Feature
Environment and safety class
Operating temperature range
Storage temperature range
Humidity (non-condensing)
Maximum installation altitude
Enclosure codes
Safety class
Pollution degree of the macro-environment
Electromagnetic compatibility (EMC)
classification
Mechanical resistance for stationary assembly
Connectivity
Authorization
Wi-Fi
Local area network
Cellular communication
Communication protocol
Physical properties
Dimensions (W x H x D)
Weight
Certification and compliance
Power supply input
Power supply output
Normal environmental conditions
Access
Equipment type
12
Description
-30 °C to +50 °C.
-40 °C to +80 °C.
5% to 95%.
3000 m above sea level.
IP55 (IEC 60529), IK10 (IEC 62262).
Safety Class I and overvoltage Category III.
Pollution degree 3.
Environment A and Environment B (in accordance with IEC
61439-1).
High resistance.
RFID reader, or using an app.
2.4/5 GHz.
Ethernet.
4G LTE-M (2G fallback supported).
OCPP 2.0.1.
250 x 366 x 184 mm.
Approximately 5.9 kg.
EV supply equipment permanently connected to AC supply
network.
AC EV supply equipment.
Indoor and outdoor use.
Equipment for locations with non-restricted access.
Stationary equipment that is wall-mounted.