CAUTION
Risk of water ingress. Rain and moisture can enter the charging station when the top cable entry is used
outdoors, which can damage the charging station.
Note
The following illustration shows a standard installation height. Observe and comply with the local accessibility
regulations.
Pre-installation checklist
Before starting the installation of the charging station, check the following:
•
The installation will be in accordance with IEC 60364 and any applicable local regulations.
•
All necessary permits have been obtained from the local authority that has jurisdiction.
•
The existing electrical load has been calculated to find the maximum operating current for the charging station
installation.
•
A miniature circuit breaker (MCB) and residual current device (RCD) are installed upstream and have the
recommended ratings. See
•
The correct specification of power supply cable has been routed to the installation area, and there is sufficient
cable length to strip and connect the wires.
•
The power supply cable will remain within its bending tolerance during and after installation.
•
The recommended tools are available on site. See
•
The plugs, screws, and drill bit used for installing the charging station are suitable for the wall structure.
14
Power supply requirements on page
Tools required on page
4. Installation instructions
15.
15.