7.
Tighten the cable gland to secure the power cable and
to maintain the IP code for the charging station.
4.5. Charging station communication
Communication cable entry is only through the left cable gland in the bottom of the charging station. A maximum
of four communication cables can enter the charging station through the gland. Blanking plugs must be in place in
the unused cable entries in the gland to maintain the IP code of the charging station.
There are three options to connect the charging station to the Internet:
Ethernet (recommended option).
Wi-Fi (see
Configuration on page
Cellular (SIM card).
Communication connections and components
Note
The communication connections and components used depend on the model of the charging station and the
required functionality.
1.
RJ45 Ethernet socket for Internet.
2.
Nano-SIM card slot for Internet.
3.
Terminals for active power control (only for Germany).
4.
RJ45 socket for dynamic load balancing.
26
34).
4. Installation instructions