Cable

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 123
EN
RCD (Residual
Current Device)
Power supply wiring
The tables below describe how to connect the power supply to the charging station, depending on the type of the
power supply and the configuration of the station.
TN and TT power supply
CAUTION
Terminals L2 and L3 must not be used.
16
RCD amperage rating: The rating must match the amperage of the charging station.
Standard installations: The RCD must be a Type A with a rated current of 20A or 40A and
have maximum 30 mA AC leakage current detection.
EV Ready installations: The RCD must be a Type A+, high immunity (for example: HPI, SI, HI,
KV, etc., depending on the RCD manufacturer).
Note
The installation, including the RCD, must be in accordance with IEC 60364 and any
applicable local regulations.
The charging station has internal DC leakage detection with tripping times and limits
compliant with IEC 61851-1:2017 Cl. 8.5. (in accordance with IEC 62955:2018 Table 2).
1-phase with neutral
4. Installation instructions
3-phase with neutral