Descargar Imprimir esta página

EVBOX Livo Manual De Instalación Y De Usuario página 28

Cable

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 123
EN
4.
Cut the power cable and strip the outer sheath so the
cable and its wires will have sufficient length to connect
to the terminal blocks in the charging station. If required,
install extra insulation on the individual wires.
CAUTION
To protect Separated Extra Low Voltage (SELV) circuits,
the stripped single-insulated wires must not touch the
components on the main board. When required, install
double insulation on the individual wires, for example
using heat-shrink tubing or insulation sleeves.
5.
Feed the power cable into the charging station as follows:
a.
Use A bottom entry or B top entry.
b.
When A bottom entry is used, make sure that the
power cable is in front of the PE cable.
24
4. Installation instructions

Publicidad

loading