Safety Information For Installation; Safety Information For Electrical Connection; Safety Information For Initial Start-Up; Unit Description - Webasto Live Instrucciones De Uso

Ocultar thumbs Ver también para Live:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 158
– The Webasto Live charging station also meters the
plug-in cycles of the charge coupling for service
EN
purposes and after 10,000 plug-in cycles, displays
a note on the web interface that an electrician
needs to inspect the plug contacts on the charge
coupling for any signs of wear. If any signs of
wear are discovered, the electrician must replace
the affected charging cables with genuine
Webasto spare parts.
– Do not attach extension cables or adapters to the
charging cable.
– Remove the charging cable by pulling on the char-
ging coupling only.
– Never clean the charging station with a high-pres-
sure cleaner or similar device.
– Switch off the power supply before cleaning the
charging sockets.
– The charging cable must not be subjected to any
strain during use.
– Ensure only persons who have read these operat-
ing instructions have access to the charging sta-
tion.
2.3

Safety information for installation

– Installation and connection of the charging station
must only be carried out by an electrician.
– Only use the supplied installation material.
– The Webasto Live safety concept is based on a
power supply system that is earthed at all times.
The electrician must ensure this requirement dur-
ing installation.
– Do not install the charging station in an explosion
sensitive area (EX zone).
– Install the charging station in such a way that the
charging cable does not block any passageways.
– Do not install the charging station in areas subject
to ammonia or air containing ammonia.
– Do not install the charging station in a location
where falling objects (e.g. extension reel or tyres)
can damage the charging station.
– The charging station is suitable for use indoors as
well as outdoors.
26
– Do not install the charging station in the vicinity of
water jets, e.g. car wash installations, high pres-
sure cleaners or garden hoses.
– Protect the charging station against damage
caused by sub-zero temperatures, hail or similar.
– The charging station is suitable for use in areas
without access restrictions.
– Protect the charging station from direct sunlight.
The charging current may be reduced at high tem-
peratures or charging may be disabled completely.
– The installation location of the charging station
should be selected such that vehicles cannot inad-
vertently collide with it. Protective measures must
be implemented if the possibility of damage can-
not be ruled out.
– Do not place the charging station into operation if
it is damaged during installation. A replacement
will be required.
2.4
Safety information for electrical
connection
– Comply with the locally applicable requirements
pertaining to electrical installations, fire protec-
tion, safety regulations and escape routes at the
intended installation location.
– Each charging station must be protected with its
own line circuit breaker and residual current circuit
breaker. See chapter 6.2, "Criteria for the electrical
connection".
– Make sure that the electrical connections are de-
energised before connecting the charging station
to the power supply.
– Make sure that the correct supply cable is used for
the power connection.
– Do not leave the charging station unattended with
the cover open.
– Register with the power supply company as re-
quired.
2.5

Safety information for initial start-up

– Initial start-up of the charging station must be car-
ried out only by an electrician.
– Prior to initial start-up, the electrician must check
that the charging station has been connected cor-
rectly.
– Do not connect a vehicle during initial start-up of
the charging station.
– Before starting-up the charging station, check the
charging cable, charging coupling and the char-
ging station for visible damage. The charging sta-
tion must not be started up if it is damaged or if
the charging cable/charging coupling is damaged.
3

Unit description

See also Fig. 1
These operating and installation instructions describe the
Webasto Live charging station. The exact unit description
is indicated on the type label of the charging station.
3.1

Description of data interface connections

See also Fig. 2
Legend
USB-A
Modbus (RS 485) external
Micro SIM-slot
RJ 45 (LAN)
USB-B
With the cover open, the data interfaces can be found on
the left-hand side in the connection area. This area is sep-
arated from the power supply area.
3.1.1
USB type A
This connection is used in host mode for a USB stick for
software or configuration updates. This connection sup-
ports the 5 V power supply up to maximum 100 mA.
3.1.2
Modbus
The data connection to a primary electricity meter can be
established for advanced power management. (see online
configuration instructions: https://webasto-
charging.com/documentation)
5110326C_OI-II_Webasto Live Multilanguage