Oven burner
To remove the front low band metal sheet placed under oven
door, to enter on oven burner nozzle.
To unscrew the burner nozzle and replace it with the one
adapted to the type of used gas consulting table 4 on section
"Oven".
To substitute the nozzle of oven spy: unscrew the cap–screw,
then unscrewing completely the nozzle and replace it with the
one adapted to the type of used gas consulting table 6. To screw
the nozzle till to bottom. To reassemble the cap–screw and the
seal washer.
Tab. 6
Butane/Propane
Methane G20
40
To substitute the by-pass minimum of oven valve: the minimum by-pass to substitute as
instruction of table 7.
After the substitution to seal the by pass with varnish.
Tab. 7
Methane
Burner
G20
Oven
200
Prime air regulation
To regulate prime air of all burners: to place the regulation ear-ring air to the measures
illustrated on following drawings.
G30/G31
20
Butane/Propane
G30/G31
110
Tab. 8
Burner
kW 8.4 A = mm
A
kW 6.0 A = mm
kW 3.5 A = mm
Valve By-pass
Methane
G20
All
open
23/72
mod. G02
Spy nozzle position
Butane/Propane
G30/G31
All
open