AWD - Recommended Wiring Schematic
Fig.6
EN 16
AWD - Set-up
Refer to the table below, alongside Fig.4 and Fig.5 to wire the AWD system correctly. Note that if any part of the
system is wired incorrectly it could cause damage to the movers or caravan tyres if all rollers do not move in the
correct directions.
Table.A - AWD - FRONT AXLE FITTING
Motor A Positive (+) cable to terminal M3+
Motor A Negative (-) cable to terminal M3-
Motor B Positive (+) cable to terminal M2+
Motor B Negative (-) cable to terminal M2-
WARNING: EACH CONTROL BOX MUST BE POWERED INDEPENDENTLY FROM THE BATTERY
THROUGH THE SAME ISOLATION SWITCH (TWO POSITIVE AND TWO NEGATIVE WIRES).
CONNECTING THE BOXES DIRECTLY (PIGGY BACKING) COULD OVERLOAD/DAMAGE
THE SYSTEM. BEFORE TURNING ON THE ISOLATION KEY ENSURE THAT BOTH NEGATIVE
CABLES ARE CONNECTED TO THEIR RESPECTIVE CONTROL BOX, FAILURE TO DO THIS
WILL ALSO CAUSE DAMAGE TO ONE/BOTH BOXES.
1.
Ensure that the motors are disengaged from the caravan wheels. Wire mover system as per tables above
referring to Fig.4 and Fig.5.
2.
Ensure the link cable is connected into port E on both control boxes.
3.
Turn on the isolation switch to supply power to both control boxes.
4.
Press button Fig.7 located on the slave control box that is powering the rear axle.
5.
Power on handset by double-pressing button Fig.1C on the handset.
6.
Set the handset to AWD mode by referring to the "Setup and Pairing" section on page 10.
7.
If required, pair the handset by referring to the "Setup and Pairing" section on page 10. Before the AWD
system will function both the handset and control box will need to be reset.
8.
Power off the handset by double-pressing button Fig.1C on the handset.
9.
Turn off the caravan isolation key to cut power to the mover.
10.
Power on system and handset and ensure that all wheels are rotating in the correct direction, installation is
now complete.
Fig.7
Fig.7
Push this button on the rear-axle slave control box.
Note: The Blue LED will turn off once activated.
Table.B - AWD - REAR AXLE FITTING
Motor A Positive (+) cable to terminal M2+
Motor A Negative (-) cable to terminal M2-
Motor B Positive (+) cable to terminal M3+
Motor B Negative (-) cable to terminal M3-
EN 17