3. Push the frame cover rearward and lift the frame
cover.
4. Install in the opposite sequence.
To examine the steering wires
The tension of the steering wires can decrease after
a period of time. This causes the adjustment of the
steering to change.
Examine and adjust the steering as follows:
1. The steering wires are correctly tightened if you can
manually move them 5 mm up or down in the groove
on the steering collar.
2. If the wires are too loose, let an authorized service
agent adjust them.
To do a check of the parking brake
1. Park the product on a hard surface that slopes
maximum 10°. Keep the product on.
WARNING:
on a grass slope when you do a check of
the parking brake.
Note:
The parking brake is electric. The parking
brake is automatically applied when the product is
stationary.
2. Make sure that the parking brake symbol shows on
the display and that the product does not move.
If the product moves, speak to your Husqvarna
servicing dealer.
1949 - 003 - 28.03.2023
Do not park the product
To replace the fuse for the power
control unit
A broken fuse for the power control unit is identified by a
burned fuse wire.
1. Make sure that the charger ON/OFF switch is set to
OFF and that the charger is disconnected from the
To disconnect the battery charger
product. Refer to
on page 17 .
2. Set the power switch to the "0" position and remove
the power switch key.
3. Remove the frame cover. Refer to
install the frame cover on page 22 .
4. Push the 4 clips and remove the cover of the power
control unit.
5. Pull out the fuse for the power control unit from the
holder.
6. Replace the broken fuse for the power control unit
with a new fuse of the same type. Refer to
data on page 35 .
Note:
If the fuse for the power control unit breaks
again a short period of time after you replace it, speak to
your Husqvarna servicing dealer.
To remove and
Technical