By pressing the F3 key, the extended synergy mode is activated,
that allows the expert to personalize and adapt the set of opti-
mised parameters to special situations.
The display shows the welding parameters synergically calcula-
ted, alongside which appear a correction factor (initially ± 0)
that can be controlled by the operator with the normal proce-
dure for modifying parameters. To return to
gic parameters, press the F3 key.
13.1 Summary of the selections and the parameters for MIG/MAG
welding in graphics MODE
By using the graphics mode you can have better immediacy and
simplicity of use in the control of the welding parameters. To
activate the graphics mode, just press the F1 key from the page
display ing the parameters. The graphics mode stays active even
when the machine is turned off. To return to the text mode, press
the F1 key again.
The graph shows the qua-
lity trend of the welding
current.
the original syner-
The status bar contains the
indicator for output volta-
ge presence, the gas out-
put indicator, and the rea-
dings of the welding volta-
ge and current.
The first line indicates the required
type of procedure (Short or Pulsed),
type and diameter of wire and type
of gas used for the welding opera-
tion. It is possible to modify it by
pressing the ESC key and making a
new selection according to the
method described above.
This is the welding current set,
which can be modified with the
keys T7.
Adjustment made by the opera-
tor to the welding voltage calcu-
lated by the synergy, which can
be changed with the T6 keys.