14.0 MEMORIZATION & MANAGEMENT OF
THE WELDING PROGRAMS
On pressing the key T3, the menu appears for the management
of the welding programs of the user. It is possible to memorise
or call up to a maximum of 60 programs.
The heading "Call" allows you to select one of the programs pre-
viously memorised. With the keys T6, you can go up or down the
menu one line at a time, while with the T7 keys you can go for-
wards or backwards by a complete page (13 programs). Once
the selection bar has been positioned over the chosen program,
press ENTER.
The heading "Memorise" allows you to file the set of welding
parameters set. The number to be assigned to its program can be
chosen by using the keys T6 and T7. You can also overwrite a
program already present by confirming the replacement and
pressing the "0" key.
With the heading "Cancellation", you can select and remove a
program which you no longer require. To carry out this opera-
tion, just move over the program to be eliminated, using the T6
or T7 keys, and press ENTER. At this point, a further confirma-
tion will be required, and by
will be cancelled.
15.0 ALARM MESSAGES
MESSAGE
Undervoltage
Overvoltage
Power module over-heating
Lack of coolant
Motor supply
High medium current
pressing the "0" key, the program
CAUSE
Shows that the mains supply
voltage has fallen below the
minimum
value
permitted.
Check the mains voltage and
press the ENTER key.
Shows that the mains supply vol-
tage has exceeded the maxi-
mum allowed. Check the mains
voltage and press the ENTER key.
Shows that the thermal cut-out
protecting the power module
has triggered. Leave the machine
to cool and press the ENTER key.
Shows that there is a lack of
coolant in the cooling circuit of
the torch or a fault in it. Press
the ENTER key after having
added any liquid required.
Shows a possible malfunction
inside the wirepulling trolley.
Call technical service.
Signals the triggering of the cur-
rent limitation on the machine
output. Press the ENTER key.
33