3. On the Open Lock screen, press the numeric key corresponding to the lock you want to open.
4. "Lock Open" will appear on-screen. Press the # key to return to the previous menu.
5. Use the keypad to select "Change Combo"
6. When prompted, enter the Master ID [00] and default Master Combination [12345678]
7. When prompted, enter the new 8-digit combination.
8. When prompted, enter the new 8-digit combination again to confirm the change.
9. Press <down> (˅) to highlight "INSTALL LOCK"
10. Press <return key> (←)
11. Enter Master ID + Combination [00 _ _ _ _ _ _ _ _]
12. If this is the Primary Lock in a system of multiple locks, scroll to "YES", then
Press <return key> (←)
13. Message appears – "Success Lock Installed"
3.5.2 Install (Electronically Pair) Lock and non-Display Keypad
For non-Display Keypads, there are two options for performing the Install process; The Standard Install Process
or Install with a Preconfigured User.
3.5.2.1 Standard Install Process
Note: Before Installation, the Master Combination change is required.
Follow these steps to change the Master Combination:
1.
Push any key to wake up the system in factory mode – it will beep and display the red function indicator
light for 10 seconds. While the red LED is illuminated, the system is awake, and the "1" key will open the
lock, or the keypad is ready process "#" set-up commands.
2. With the system awake, enter the following to change the Master Combination:
i.
ii.
iii.
iv.
v.
If successful, the keypad will respond with 3 high beeps and 3 green LED flashes.
Follow these steps to "INSTALL" (logically, electronically pair) a safe lock to a non-OLED Display Keypad:
1.
Push any key to wake up the system in factory mode – it will beep and display the red function indicator
light for 10 seconds. While the red LED is illuminated, the system is awake, and the "1" key will open the
lock, or the keypad is ready process "#" set-up commands.
2. a) Press 1 to test the opening of the lock, OR
b) With the system awake, enter the following:
i.
ii.
iii.
3. The lock is now installed (paired with the keypad). 3 high beeps and 3 green LED flashes will occur to
signal that the lock is now Installed (paired with the keypad).
Note: Once "Installed", there is no need to "wake up" the system before another intended command
sequence.
The pound sign (#) followed by the number 52
Enter the default Master ID and Master Combination [00 12345678]
Enter the Master ID and a new, unique Master Combination [00 _ _ _ _ _ _ _ _ ]
Confirm the Master ID and new Master Combination by entering them again
[00 _ _ _ _ _ _ _ _ ]
Press the <return key> (←)
The pound sign (#) followed by the number 22
The Master ID and Master Combination [00 _ _ _ _ _ _ _ _ ]
Press the <return key> (←)
dormakaba USA Inc. System User Guide 7040.1121 Rev E2 10/22 | 32