To recap, the total keystroke and keypad feedback sequence is as follows:
<return key> + #50
12345678 (Combo) + 00 (ID) + [New 8-digit Combo] + 00 (ID) + [New 8-digit Combo] + <return key>
Green Beeps and Flashes)
Beeps and Flashes)
Note: Manager and Standard users should change their combinations before use, though it is not required with
the default system settings.
3.6 Open a Lock
3.6.3 Open a Lock – Display Keypad
Follow these steps to open a Safe Lock on a Display Keypad:
1.
Enter the User ID.
2. Enter the User Combination.
3. If required, present and click the button on the user fob when requested.
4. If required, enter second User ID and User Combination.
5. The lock's latch will open, and the screen will display Lock Open. After 3 seconds, the lock's latch will close.
If Time Delay is in effect, menus will be different. Consult
information.
3.6.4 Open a Lock – Non-Display Keypad
Follow these steps to open a Safe Lock on a non-Display Keypad:
1.
Enter the User ID and Combination.
2. The lock's latch will open. After 3 seconds, the lock's latch will close.
If Time Delay is in effect, the lock will not automatically open. Consult
document for more information.
3.6.5 Open a Lock – Remote Disable
With the application of the Alarm Box, the opening sequence can be disabled by asserting a signal on the Alarm
Box. The signal may come from an external alarming system that could be connected to this lock to prevent it
from opening.
Please observe the following while using the Remote Disable:
The Remote Disable assertion will not block users from accessing the menus on a Display Keypad
•
The signal must be asserted prior to the user authentication for it to be recognized by the system
•
Duress combinations will still trigger the alarm signal, even if Remote Disable is asserted
•
A Keypad with a display will show 'Lock #x NOT open' when the Remove Disable is asserted. The 'x' would
•
be replaced by a lock that is targeted to be opened
(3 Green Beeps and Flashes)
(Long Red LED)
dormakaba USA Inc. System User Guide 7040.1121 Rev E2 10/22 | 34