5. Press the corresponding number key to select a lock.
Note: If only a single lock is installed, this screen will not appear.
6. Select either "Yes" or "No" to confirm.
Note: Confirmation is only required when uninstalling the last (primary) lock.
7. "Success Uninstalled" appears on screen and the Keypad will beep three times and flash a green LED once
complete.
Note: Lock #1 cannot be uninstalled until all other locks are uninstalled or reset.
3.13.2.2 Uninstall a Lock – Non-Display Keypad
Follow these steps to Uninstall a safe lock on a non-Display Keypad:
1.
Using the Keypad, input #23 + Master ID and Combination + <return key> (←).
2. The Keypad will beep three times and flash a green LED once complete.
3.13.3 Reset a Lock
Each LA GARD safe lock can be reset to factory defaults. This function is particularly useful when switching out
a piece of the overall System that has a different model number than the previous version. A lock reset can be
done one of two ways:
1.
Master Reset via the Keypad (both Display and Non-Display versions)
2. Mechanical Reset via the Reset Box (Item/Order # 704065).
When a lock is reset:
The Master Combination is reverted to the default (1-2-3-4-5-6-7-8).
All Managers and Standard Users are deleted.
All System and lock settings will be reset to their default.
All locks will be uninstalled and unpaired from any Keypad.
Two items will not be deleted:
1.
Audits.
2. Open count.
Note: Reset operations via reset box or via Master code reset will result in
a. UTC time in lock will not be reset unless power has been removed for a period of time.
b. DST rules tables will be defaulted to be no adjustments for any time zones.
c. Time Zone will be set to GMT.
d. DST observed flag will be set to true.
For more information, refer to section
3.13.3.1 Master Reset – Display Keypad
This method requires knowledge of the Master combination. In a multi-lock System, Lock #1 must be reset last.
Follow these steps to perform a Master reset using a Display Keypad:
1.
Enter the Master ID and Master Combination.
2. From the Main Menu, navigate through the options to select "System".
3.17 "Time/Date Rules in LA GARD 700 Series
dormakaba USA Inc. System User Guide 7040.1121 Rev E2 10/22 | 40
Locks".