Step 3
Change
Manager
Change
Combination:
Combinations
#52
(Recommended)
Change
Standard User
Combination:
#52
Other System Function Settings
The commands below are shown with the
will respond with a short red flash and low beep signaling that the lock is ignoring that key and waiting for your
# command.
Action
Command String
Set/Change
#11 00 (ID) _ _ _ _ _ _ _ _ (Combo) 6
Combination
#11 00 (ID) _ _ _ _ _ _ _ _ (Combo) 7
Length: #11
#11 00 (ID) _ _ _ _ _ _ _ _ (Combo) 8
#11 00 (ID) _ _ _ _ _ _ _ _ (Combo) 9
Set Force
Force Combination Change On/Off:
Change
#17 (Default Off)
Combo
Do Not Require Combo Change:
#17 00 (ID) _ _ _ _ _ _ _ _ (Combo) 0
Require Combo Change:
#17 00 (ID) _ _ _ _ _ _ _ _ (Combo) 1
Set Buzzer
#41 _ _ (ID) _ _ _ _ _ _ (Combo) 0
On/Off: #41
#41 _ _ (ID) _ _ _ _ _ _ (Combo) 1
Enable FW
#99 _ _ (ID) _ _ _ _ _ _ (Combo)
Update Port:
#99
#52 01 (ID) 123456 (Combo)
01 (ID) _ _ _ _ _ _ (New 6 Digit Combo)
01 (ID) _ _ _ _ _ _ (New Combo)
#52 02 (ID) 123456 (Combo)
02 (ID) _ _ _ _ _ _ (New 6 Digit Combo)
02 (ID) _ _ _ _ _ _ (New Combo)
as the key press for waking the system. When not needed the lock
for 6 digit
for 7 digit
for 8 digit
for 9 digit
for Buzzer Off
for Buzzer On
dormakaba USA Inc. System User Guide 7040.1121 Rev E2 10/22 | 65
Keypad:
Lock: Combination Changed
Keypad:
Lock: Combination Changed
Requirement
Result
Keypad:
Master Only
Lock: Combo length changed
Note: Impact
for Manager and Standard
to existing
Users.
user
combinations
Note: Master Combo length
does not change from 8
characters. Changing the
Combo Length will impact
existing user combos.
* Use the Master to Reset
User combos after changing
the Combo Length. Users
should then change their
combo for first use.
Master Only
Keypad:
Lock: Require Combination
Change on First Use will be
On/Off
Master or
Keypad:
Manager
Lock: Buzzer is On/Off
Master or
Keypad:
Manager
Lock: Firmware can be
updated by 700 Series
Software.