"Status"
o
"Cancel"
o
"FOB Override"
o
"Notes"
o
Multiple Lock System
"Status"
o
"Open Lock"
o
"Cancel TD"
o
reports the time remaining in either the Delay Period or the Confirmation Window
(Confirmation Window is shown for a valid user without open privilege, e.g., Master or
Audit Only User)
cancels the Time Delay for the lock
only available if the Keypad has the BLE option AND the user accessing the Time Delay
menu possesses open privileges
prompts the user to present the fob for overriding Time Delay; if fob is authorized to
override the Time Delay, the lock is opened
if the lock is in the Confirmation Window, and the user is authorized to open the lock,
then the lock will open, otherwise the user is shown the Menu (Example: an Audit Only
User)
if the user is authorized to open the lock and possesses Time Delay Override privileges,
the lock will open after the credential Keypad during the Delay Period
provides list reporting for each installed lock and the status of the lock. The list can be
navigated through using the Up and Down keys. Will report the status as:
"Dly Disable"
"Dly Inactive"
time Delay is enabled, but the lock is not in the Delay Period, nor the
o
Confirmation Window
"Delay: mm:ss"
the lock is in the Delay Period and shows the time in minutes and seconds,
o
using the Count Feedback mode assigned for the Delay Period
"Open: mm:ss"
the lock is in the Confirmation Window and shows the time in minutes and
o
seconds, using the Count Feedback mode assigned for the Delay Period
the Master user does not see this option
the User is prompted to select a lock. Only locks which the user is authorized to open
are shown in the selection screen
Selected Lock has Time Delay disabled
the Lock will open
o
Selected Lock has Time Delay, but it's inactive
if the Lock allows Time Delay Override and the user has Override
o
privileges, then the lock will open
Time Delay will initiate for the selected lock
o
Selected Lock is in the Delay Period
if the User has Override privileges, the lock will open
o
if the User does not possess Override privileges, the lock will not open and
o
will remain in the Delay Period. The Keypad will return to the Time Delay
'Wake-Up' screen
Selected Lock is in the Confirmation Window
the Lock opens