temperature setting value. When the mix temperature in the hopper
reaches or is lower than the hopper pre-cooling temperature setting value,
the pre-cooling compressor will stop; when the temperature of the mix in
the hopper rises to the hopper pre-cooling temperature setting value + 2
degrees, the pre-cooling compressor starts. When the temperature of the
mix in the refrigeration cylinder reaches or is lower than the refrigeration
cylinder pre-cooling temperature setting value, the main compressor stops,
and the beater motor stops after 15 seconds. When the mix temperature in
the refrigeration cylinder rises to the refrigeration cylinder pre-cooling
temperature setting value + 2 degrees When, the beater motor turns on,
and the main compressor turns on after 3 seconds, and so on.
◆Auto Function
Press "
", the "AUTO" and "FRESH" icons will light up. The pre-cooling
press is controlled by the pre-cooling temperature setting value of the
hopper. When the temperature of the mix in the hopper reaches or is lower
than the pre-cooling temperature setting value of the hopper, the
pre-cooling compressor will stop; when the temperature of the mix in the
hopper rises to the hopper pre-cooling temperature setting value + 2
degrees, the pre-cooling compressor starts. When the hardness value
reaches 99, the main compressor stops, the betaer motor stops after 15
seconds, and enters the waiting state. When the waiting time reaches the
machine cycle restart time setting, the beater motor starts, and the main
compressor starts after 3 seconds, and so on.
◆Defrost Function
In standby mode, press the "Defrost" button, the "AUTO" and "CLEAR"
icons flash, and the machine enters the defrost function. The main
compressor, beater motor, and defrost solenoid valve are controlled by