Do not damage the condenser fins when cleaning.
D. Belt Adjustment
After the machine has been used for a period of time, the belt of the mixing
system may be stretched and needs to be adjusted in time. When the
machine is shut down and powered off, dismantle the hoarding and adjust
the belt tensioning bolts to ensure proper tightness.
VI.Trouble Shooting Guide
We have listed some trouble shooting and corresponding solutions of ice
cream machine in below sheet. You can follow the instruction and solve
the simple issues by yourself, if the problem persists or too complex, don't
handle it by yourself, please contact our professional technicians to avoid
any unnecessary loss.
Issues
Power cord disconnected
Machine
does not
work.
Clean
mode
does not
work.
Causes
Protection
circuit breaker open
Protection circuit
operation
loose connection
The stirring motor is
broken
Check the power supply and
connect it securely
Wait for the circuit breaker to be
manually reset before starting
Restart after troubleshooting
Check the connections and
connect them securely
Repair or replace motor
- 24 -
Treatment
again