Advanced Program Group
32
32 bit parameter.
A056 [Relay Out Level]
Sets the trip point for the digital output relay if the value of A055
A055 Setting
Min/Max
6
0/240 Hz
7
0/180%
8
0/815 Volts
Values
Default
Min/Max:
Display:
A067 [Accel Time 2]
Sets the rate of acceleration for all speed increases except jog.
Maximum Freq
=
Accel Rate
Accel Time
Values
Default
Min/Max:
Display:
[Maximum Freq]
Speed
0
[Accel Time]
0
A068 [Decel Time 2]
Sets the rate of deceleration for all speed decreases except jog.
Maximum Freq
=
Decel Rate
Decel Time
Values
Default
Min/Max:
Display:
[Maximum Freq]
Speed
0
[Accel Time]
0
0.0
0.0/9999
0.1 – 1
20.0 Secs
0.0/600.0 Secs
0.1 Secs
[Decel Time]
Time
20.0 Secs
0.1/600.0 Secs
0.1 Secs
[Decel Time]
Time
Programming and Parameters
(continued)
Related Parameter(s):
[Relay Out Sel]
Related Parameter(s):
Related Parameter(s):
3-15
A055
is 6, 7 or 8.
P039