3-32
Programming and Parameters
Advanced Program Group
A113 [Anlg In4-20mA Hi]
Stop drive before changing this parameter.
Sets the analog input level that corresponds to
P038
[Speed Reference].
Analog inversion can be accomplished by setting this value smaller than A112 [4-20mA Analog Input
Low].
Values
Default
Min/Max:
Display:
A114 [Slip Hertz @ FLA]
Compensates for the inherent slip in an induction motor. This frequency is added to the commanded
output frequency based on motor current.
Values
Default
Min/Max:
Display:
A118 [Current Limit 2]
Maximum output current allowed before current limiting occurs. This parameter is only active if
A051
-
A054
[Digital Inx Sel] is set to 25 "Current Lmt2" and is active.
Values
Default
Min/Max:
Display:
A119 [Skip Frequency]
Sets the frequency at which the drive will not operate.
A setting of 0 disables this parameter.
Values
Default
Min/Max:
Display:
(continued)
Related Parameter(s): d021, P035,
P035
[Maximum Freq] if a 4-20mA input is used by
100.0%
0.0/100.0%
0.1%
2.0 Hz
0.0/10.0 Hz
0.1 Hz
Related Parameter(s): P033, A051-A054,
Drive Rated Amps × 1.5
0.1/(Drive Rated Amps × 1.8)
0.1 Amps
0 Hz
0/400 Hz
1 Hz
Related Parameter(s):
Related Parameter(s):
P038
P033
A089