SOSTITUZIONE LIQUIDO DI RAFFREDDAMENTO
- Unscrew the three screws (1).
- Move the clamp (2) with the ABS control unit and
the canister.
WARNING*: Coolant shall be replaced with cold
engine and coolant.
Emptying procedure
- Place a vessel on the R.H. side of the cylinder, under
the coolant drain screw (3). FIRST remove the screw
(3) then SLOWLY open the R.H. radiator cap (4);
slope the motorcycle on the right side to drain the
coolant easily in the vessel. Reassemble the screw
(3) (coupling torque 10 Nm/ 1 Kgm/ 7,38 ft/lb).
Filling procedure
- Pour the mount of liquid prescribed into the
radiator and re-position the cap (4)
- Take the motor to temperature to eliminate any
air bubbles.
1
2
- Allow the coolant to cool down then remove cap
(4) and check the level as explained under "Cool-
ant level check".
1a
- Periodically check the connecting hoses (see
"Scheduled Maintenance Chart"): this will avoid
coolant leakage and consequent engine seizure:
If hoses (A) show cracks, swelling or hardening
due to sheaths desiccation, their replacement
shall be advisable.
- Check the correct tightening of the clamps (B).
- Re-mount the clamp with the ABS control unit
and the three screws (1).
3
WARNING*: The screw (15a) is longer and must
be mounted exactly in the position indicated
in the figure.
3
A
4
B
EN - 31