Malfunctions
Steam is constantly
escaping from
the safety valve /
automatic cooking
system (does not
apply to the pre-
cook phase)
The turn knob
cannot be pulled
back and the
pressure cooker
cannot be opened
this way.
o
1.
y
.
e
80 5800 6330 | 001
Operating Instructions
Cause
Safety valve ball is not
positioned properly in the
valve
Safety opening system
blocked.
Remedy
1. Completely release the pressure from the pot as
described in Chapter 6.6 and open it.
as described in Chapter 5.1.
2. Remove lid handle
B
3. Check safety valve
and/or position of the metal
7
ball in the lid.
4. Close the pot again as described in Chapter 5.3.
1. Completely release the pressure from the pot as
described in Chapter 6.6 and open it.
2. Push knob
forwards and back several times.