Descargar Imprimir esta página

How To Use Peak Voltage Adapter; Attention Of Measurement; Measurement Procedure - TOHATSU EverRun MX50D2 Manual De Servicio

Ocultar thumbs Ver también para EverRun MX50D2:

Publicidad

Electrical System
V
a
b
c
8-8
All manuals and user guides at all-guides.com
3.How to use Peak Voltage
Adapter

Attention of measurement

• Before measuring the peak voltage, check each wiring for
proper connection and corrosion.
• Connected and disconnected, there is the respective value
in peak voltage.
• As for usual system measurement in connected, as for coil
single item measures in disconnected.
• Connected a state where the cable terminal of the outboard
motor is connected, disconnected a state where the cable
terminal of the outboard motor is disconnected.
Measurement
1) Place the outboard motor in test tank for ready to engine
starting.
2) Attach tachometer to outboard motor. (without cranking)
3) Attach peak voltage adapter to tester.
4) Set selector of digital circuit tester to "DCV" mode.
5) Connect pin a of peak voltage adapter to measurement
pin b.
procedure:
The peak voltage adapter plug a, there is a
positive pin and negative pin. Connect Red
(positive) pin of peak voltage adapter to positive
terminal of digital circuit tester.
• Insert stick pin, and then pinch the testing clip.
• Readings the same value, so there is no polarity
in peak voltage adapter pins, connect to each
measuring terminals c.
• To connect, refer to wiring color diagrams of
each models. Indicate wire color on the outboard
motor.
GB
2st 50D2 2011

Publicidad

Capítulos

loading

Este manual también es adecuado para:

Everrun mwx 50d2