Descargar Imprimir esta página

Ausa D 600 AP Manual Del Operador página 72

Publicidad

72
Cuadro de averías motor Deutz
Código
Código
parpadeo
167
6-1-5
Timeout error of CAN-Transmit-Frame EEC3.
Timeout error of CAN-Transmit-Frame EEC3VOL1. Engine
168
7-6-3
send messages.
Timeout error of CAN-Transmit-Frame EEC3VOL2. Engine
169
7-6-4
send messages.
Timeout error of CAN-Receive-Frame ComEngPrt. Engine
171
3-3-3
Protection.
172
6-1-8
Engine shut off request through CAN.
174
3-3-4
Timeout error of CAN-Transmit-Frame ERC1.
178
6-2-3
Timeout error of CAN-Transmit-Frame FlEco.
Timeout CAN-message FunModCtl. Function Mode
179
5-2-7
Control.
193
7-6-5
Timeout DFC for NOxSensGlbReqTx.
196
6-3-8
DFC SAE J1939 error.
Timeout error of CAN-Receive-Frame PrHtEnCmd. Pre-
198
3-3-7
heat command, engine command.
Timeout error of CAN-Receive-Frame UAA10. AGS sensor
202
6-7-8
service message.
Timeout error of CAN-Receive-Frame UAA11. AGS sensor
203
6-7-8
data.
Timeout error of CAN-Receive-Message RxEngPres.
212
6-7-8
Status Burner Air Pump.
273
6-4-9
DFC SAE J1939 error.
281
1-1-8
Timeout error of CAN-Receive-Frame Active TSC1AE.
282
1-1-8
Timeout error of CAN-Receive-Frame Passive TSC1AE.
283
1-1-9
Timeout error of CAN-Receive-Frame Active TSC1AR.
284
1-1-9
Timeout error of CAN-Receive-Frame Passive TSC1AR.
291
1-1-9
Timeout error of CAN-Receive-Frame TSC1TE - active.
Passive timeout error of CAN-Receive-Frame TSC1TE.
292
1-1-9
Setpoint.
293
1-1-8
Timeout error of CAN-Receive-Frame TSC1TR.
294
1-1-8
Passive timeout error of CAN-Receive-Frame TSC1TR.
Timeout error of CAN-Transmit-Frame TrbCH. Status
299
6-5-5
Wastegate.
Timeout error of CAN-Receive-Frame TSC1AE. Traction
300
1-1-8
Control.
301
1-1-9
Timeout error of CAN-Receive-Frame TSC1AR. Retarder.
305
1-1-8
Timeout error of CAN-Receive-Frame TSC1TE. Setpoint.
Timeout Error of CAN-Receive-Frame TSC1TR. control
306
1-1-9
signal
313
6-7-9
Timeout error of CAN-Transmit-Frame UAA11.
Timeout error of CAN-Transmit-Frame UAA1 on CAN 2.
322
6-7-9
Control burner air pump.
360
7-3-7
Powerstage diagnosis disabled. High battery voltage.
361
7-3-7
Powerstage diagnosis disabled. Low battery voltage.
362
3-2-9
Engine brake Pre-Selection switch. Plausibility error.
376
2-8-1
Access error EEPROM memory (delete).
377
2-8-1
Access error EEPROM memory (read).
378
2-8-1
Access error EEPROM memory (write).
381
6-9-3
Physical range check low for EGR differential pressure.
384
4-1-5
Actuator EGR valve. Powerstage over temperature.
387
5-5-5
Internal software error ECU. Injection cut off.
Engine speed above warning threshold.
388
2-1-4
Overspeed detection in component engine protection.
Engine speed above warning threshold
389
2-1-4
(FOC-Level 1).
Engine speed above warning threshold
390
2-1-4
(FOC-Level 2).
Descripción en Inglés
D 600 AP / D 600 AP PLUS / D 600 APG / D 600 APG PLUS
Código
Código
parpadeo
Engine speed above warning threshold
391
2-1-4
(Overrun Mode).
Ambient air pressure received from a CAN-bus is reported
411
2-9-2
as defective.
Sensor error ambient air pressure. Signal range check
412
2-9-2
high.
Sensor error ambient air pressure. Signal range check
413
2-9-2
low.
Environment temperature sensor, temperature above
415
3-1-2
upper physical threshold.
416
3-1-2
Environment temperature physical range check low.
Sensor error SCR-System environment temperature.
417
3-1-2
DPF-System air inlet temperature, signal range check
high.
Sensor error SCR-System environment temperature.
418
3-1-2
DPF-System air inlet temperature, signal range check low.
419
2-1-2
Sensor camshaft speed, disturbed signal.
Sensor camshaft detection.
420
2-1-2
Out of range, signal disrupted, no signal.
Offset angle between crank- and camshaft-sensor is too
421
2-1-3
large.
Sensor crankshaft detection.
422
2-1-2
Out of range, signal disrupted or no signal.
Speed detection, out of range, signal disrupted or no
423
2-1-2
signal.
455
2-3-8
PWM-Signal fan, open load or short-circuit ground.
457
2-3-8
PWM-Signal fan, short-circuit to battery.
458
2-3-8
PWM-Signal fan, open load or short circuit to ground
Fan speed sensor, electrical error, signal disturbed or very
459
2-3-8
low fan speed.
Sensor error fan speed.
460
2-3-8
Signal range check high or engine speed resp. fan speed
too big.
Sensor error fan speed, signal range check low or fan
461
2-3-8
speed too low.
462
2-3-8
High fan speed, warning threshold exceeded.
463
2-3-8
High fan speed, shut off threshold exceeded.
464
2-2-8
Sensor error water in fuel, signal range check high.
465
2-2-8
Sensor error water in fuel, signal range check low.
472
2-1-6
Sensor error low fuel pressure, signal range check high.
473
2-1-6
Sensor error low fuel pressure, signal range check low.
474
2-1-6
Low fuel pressure, warning threshold exceeded.
475
2-1-6
Low fuel pressure, shut off threshold exceeded.
483
2-2-7
Fuel temperature not plausible.
Sensor error gearbox oil temperature, signal range check
486
1-3-3
high.
Sensor error gearbox oil temperature, signal range check
487
1-3-3
low.
Physical range check high for exhaust gas temperature
488
1-3-3
upstrem (SCR-CAT).
Shutoff condition
489
1-3-3
No detail informationen!
HCI dosing valve (DV1); overcurrent at the end of the
500
1-6-5
injection phase
501
1-6-6
HCI dosing valve (DV1): Powerstage overtemperature.
502
1-5-9
HCI dosing valve (DV1): Short circuit to battery.
Short circuit to battery high side, HCI dosing valve
503
1-6-4
(DV1).
504
1-5-9
HCI dosing valve (DV1): Short circuit to ground.
HCI dosing valve (DV1): Short circuit high side
505
1-6-4
powerstage.
Descripción en Inglés

Publicidad

loading

Este manual también es adecuado para:

D 600 ap plusD 600 apgD 600 apg plus