80
Cuadro de averías motor Deutz
Código
Código
parpadeo
1655
1-3-8
DEF tank, DEF level below first warning threshold
1656
1-3-8
DEF tank, DEF level below second warning threshold
Control of the SCR system; If the start stop counter
(EPA-Counter) exceeds the threshold SCRCtl_
ctEngStrtStopThresh_C. This counter will increment only
1658
1-9-6
once in each driving cycle in case of an SCR error. If the
counter reaches the threshold, the DFC will be set to
inhibit the engine start
Engine will not be started, because of EPA-Counter
1659
9-3-8
Timeout error of CAN-Transmit-Frame A1DOC
1660
9-3-9
Timeout error of CAN-Transmit-Frame AT1S
1661
1-9-4
Timeout error of CAN-Transmit-Frame SCR2
1662
9-4-1
Timeout error of CAN-Transmit-Frame SCR3
1663
9-2-1
Timeout error of CAN-Transmit-Frame DPFBrnAirPmpCtl
1664
9-2-2
Timeout error of CAN-Transmit-Frame ComDPFBrnPT
1665
9-2-3
Timeout error of CAN-Transmit-Frame ComDPFC1
1666
9-2-4
Timeout error of CAN-Transmit-Frame ComDPFHisDat.
1667
9-2-5
Timeout error of CAN-Transmit-Frame ComDPFTstMon
Timeout error of CAN-Transmit-Frame ComEGRMsFlw
1668
9-2-9
(EGR Steller)
Timeout error of CAN-Transmit-Frame ComEGRTVActr
1669
9-3-2
(EGR actuator)
1670
9-3-4
Timeout error of CAN-Transmit-Frame ComETVActrTO.
1671
9-3-6
Timeout ComIntake Throttle Valve Actr.
1672
9-4-2
Timeout error of CAN-Receive-Frame ComRxCM1
Timeout error of CAN-Receive-Frame
1675
9-2-7
ComRxDPFBrnAirPmp
1676
9-2-8
Timeout error of CAN-Receive-Frame ComRxDPFCtl.
Timeout error of CAN-Receive-Frame ComRxEGRMsFlw1
1677
1-9-5
(EGR actuator)
Timeout error of CAN-Receive-Frame ComRxEGRMsFlw2
1678
9-3-1
(EGR actuator)
Timeout error of CAN-Receive-Frame ComRxEGRTVActr
1679
9-3-3
(EGR actuator)
1680
9-3-5
Timeout error of CAN-Receive-Frame ComRxETVActr
1681
9-3-7
Timeout error of CAN-Receive-Frame ComRxITVActr
1682
9-4-4
Timeout error of CAN-Receive-Frame ComRxSCRHtDiag
Timeout error of CAN-Receive-Frame ComRxTrbChActr
1683
9-4-5
(wastegate actuator)
Timeout error of CAN-Receive-Frame ComRxUQSens
1684
9-4-6
(Urea quality)
1685
9-4-7
Timeout error of CAN-Receive-Frame ComSCRHtCtl
1686
9-4-8
Timeout error of CAN-Receive-Frame ComTxAT1IMG
Timeout error of CAN-Receive-Frame ComTxTrbChActr
1687
9-4-9
(Wastegate actuator)
1698
9-5-6
HMI system; set if restore button blocked
1699
9-5-7
DPF, ash load exceeds the shutoff threshold
1700
9-5-7
DPF, ash load exceeds the warning threshold
1701
9-5-8
DPF, soot load exceeds the shutoff threshold
1702
9-5-8
DPF, soot load exceeds the service request threshold
1703
9-5-8
DPF, soot load exceeds the warning threshold
1705
9-7-2
Timeout error of CAN-Receive-Frame ComRxEBC2.
1706
9-7-3
Fancontrol; time out for fan governing
1708
9-7-5
Fan; short circuit battery or open load
1709
9-7-5
Fan; short circuit ground
1710
9-7-6
Fan; in/outlet valve 1; open load
1712
9-7-6
Fan; in/outlet valve 1; short circuit battery
1713
9-7-6
Fan; in/outlet valve 1; open load ground
1714
9-7-7
Fan; in/outlet valve 2; open load
Descripción en Inglés
D 600 AP / D 600 AP PLUS / D 600 APG / D 600 APG PLUS
Código
Código
parpadeo
1716
9-7-7
Fan; in/outlet valve 2; short circuit battery
1717
9-7-7
Fan; in/outlet valve 2; open load ground
1718
9-7-8
Fan; fancontrol; angle sensor defect
1719
9-7-9
Fan; fancontrol; fan or valve defect
1752
4-1-5
EGR actuator, actuator blocked
1753
4-1-5
EGR actuator, CAN error
1754
4-1-5
EGR actuator, EOL calibration error
1755
4-1-5
EGR Actuator, internal electrical fault
1756
4-1-5
EGR actuator, learning process aborted
1757
4-1-5
EGR actuator current is above maximum threshold
EGR actuator supply voltage is above the maximum
1758
4-1-5
threshold
EGR actuator supply voltage is below minimum
1759
4-1-5
threshold.
1760
4-1-5
EGR actuator, learning process out of range
1761
4-1-5
EGR actuator, broken spring detected.
1762
4-1-5
EGR actuator, temperature high.
1763
4-1-5
EGR actuator, temperature critical high
1788
8-1-4
Turbocharger wastegate, mechanical blocking detected.
1789
8-1-4
Turbocharger wastegate, CAN Error
1790
8-1-4
Turbocharger wastegate, EOL calibration error.
1791
8-1-4
Turbocharger wastegate, internal electrical error
1792
8-1-4
Turbocharger wastegate, learning process aborted.
Turbocharger wastegate, current above maximum
1793
8-1-4
threshold.
Turbocharger wastegate, supply voltage above maximum
1794
8-1-4
threshold.
Turbocharger wastegate, supply voltage below minimum
1795
8-1-4
threshold.
1796
8-1-4
Turbocharger wastegate, learning process out of range.
1797
8-1-4
Turbocharger wastegate, broken spring detected.
1799
8-1-4
Turbocharger wastegate, temperature critical high.
1827
1-9-2
DEF dosing valve, dosing valve blocked
Engine starter, plausibility error of starter release
1857
5-5-5
condition
1858
9-6-6
SCR-System, reverting valve blocked
1859
9-9-3
SCR-CAT, Nox emissions above maximum threshold
NOx-Sensor after SCR-Cat: Nox-Sensor dew point
1860
2-4-6
problem or plausibility problem
NOx-Sensor before SCR-Cat: Nox-Sensor dew point
1861
2-4-8
problem or plausibility problem
1863
9-9-5
SCR System, DEF suction line blocked
1864
9-9-6
SCR System, DEF pressure out of range
Exhaust temperature sensor upstream SCR, plausibility
1865
6-6-8
error
1866
6-6-5
DEF supply module pressure, plausibility error
1867
8-9-4
Supply module heater temperature, plausibility error
1868
8-9-4
Supply module temperature, plausibility error
1869
1-2-9
DEF tank level, plausibility error
1870
6-6-9
Urea tank temperature outside of plausible thresholds
1874
9-7-1
Urea Quality Sensor; Timeout CAN message
Urea tank level & urea tank temperature via CAN bus,
1875
9-9-7
timeout of CAN message
1880
1-3-8
DEF tank, DEF level below third warning threshold
exhaust gas temperature sensors up- and downstream
1881
6-8-3
DOC are physically swapped
Descripción en Inglés