Descargar Imprimir esta página

Ausa D 600 AP Manual Del Operador página 73

Publicidad

D 600 AP / D 600 AP PLUS / D 600 APG / D 600 APG PLUS
Cuadro de averías motor Deutz
Código
Código
parpadeo
Sensor HCI dosing valve (DV1) downstream pressure:
506
7-1-9
Plausibility error.
HCI dosing valve (DV1) downstream pressure: Physical
508
7-1-9
range check high. Shut off regeneration.
HCI dosing valve (DV1) downstream pressure: Physical
511
7-1-9
range check low. Shut off regeneration.
Sensor error HCI dosing valve (DV1) downstream
514
7-1-9
pressure: Signal range check high.
Sensor error HCI dosing valve (DV1) downstream
515
7-1-9
pressure: Signal range check low.
Sensor error DV1 & DV2 upstream pressure: Signal range
525
7-1-8
check low.
Sensor error DV1 & DV2 upstream temperature: Signal
534
7-1-7
range check high.
Sensor error DV1 & DV2 upstream temperature: Signal
535
7-1-7
range check low.
542
3-1-4
Hydraulic oil temperature check for Shut off condition.
543
263
Cold start aid relay error.
544
263
Cold start aid relay: Open load.
545
263
Cold start aid relay open load.
547
263
Cold start aid relay: Over temperature error.
549
263
Intake Air Heater Device: Short circuit to battery.
551
263
Check of missing injector adjustment value programming
559
1-5-8
(IMA) injector 1.
Check of missing injector adjustment value programming
560
1-5-8
(IMA) injector 2.
Check of missing injector adjustment value programming
561
1-5-8
(IMA) injector 3.
Check of missing injector adjustment value programming
562
1-5-8
(IMA) injector 4.
Check of missing injector adjustment value programming
563
1-5-8
(IMA) injector 5.
Check of missing injector adjustment value programming
564
1-5-8
(IMA) injector 6.
565
151
Injector cylinder-bank 1: Short circuit.
566
152
Injector cylinder-bank 2: Short circuit.
567
153
Injector powerstage output defect.
Injector 1 (in firing order): Interruption of electric
568
154
connection.
Injector 2 (in firing order): Interruption of electric
569
155
connection.
Injector 3 (in firing order): Interruption of electric
570
156
connection.
Injector 4 (in firing order): Interruption of electric
571
161
connection.
Injector 5 (in firing order): Interruption of electric
572
162
connection.
Injector 6 (in firing order): Interruption of electric
573
163
connection.
special pattern for special cases
575
1-5-5
No detail informationen!
special pattern for special cases
576
1-5-6
No detail informationen!
special pattern for special cases
577
1-6-1
No detail informationen!
special pattern for special cases
578
1-6-2
No detail informationen!
special pattern for special cases
579
1-6-3
No detail informationen!
580
154
Injector 1 (in firing order): Short circuit.
581
155
Injector 2 (in firing order): Short circuit.
Descripción en Inglés
Código
Código
parpadeo
582
156
Injector 3 (in firing order): Short circuit.
583
161
Injector 4 (in firing order): Short circuit.
584
162
Injector 5 (in firing order): Short circuit.
585
163
Injector 6 (in firing order): Short circuit.
High side to low side short circuit in the injector 5 (in firing
590
1-6-2
order)
High side to low side short circuit in the injector 6 (in firing
591
1-6-3
order)
592
135
Metering unit (Fuel-System): Open load.
Metering unit (Fuel-System): Powerstage over
593
135
temperature.
Metering unit (Fuel-System): Short circuit to battery,
594
135
highside.
Metering unit (Fuel-System): Short circuit to ground, high
595
135
side.
Metering unit (Fuel-System): Short circuit to battery, low
596
135
side.
Metering Unit (Fuel-System): Short circuit to ground, low
597
135
side
598
1-3-5
Metering unit, short circuit to battery
599
1-3-5
Metering unit, short circuit to ground
Too many recognized misfires in cylinder 2
605
2-4-1
(in firing order)
Too many recognized misfires in cylinder 4
607
2-4-1
(in firing order)
Too many recognized misfires in cylinder 5
608
2-4-1
(in firing order)
Too many recognized misfires in cylinder 6
609
2-4-1
(in firing order)
610
2-4-1
-
Misfire detection monitoring
611
2-4-1
No detail informationen!
612
555
Internal ECU monitoring detection reported error
ECU reported internal software error
613
555
Internal ECU monitoring detection reported error
614
555
ECU reported internal software error
615
555
ECU reported internal software error.
616
555
ECU reported internal software error
617
555
ECU reported internal software error
618
555
ECU reported internal software error
619
555
Injection system,electrical error injectors
620
555
ECU reported internal software error
621
555
ECU reported internal software error
623
555
ECU reported internal software error
624
555
ECU reported internal software error
625
555
ECU reported internal software error
627
555
ECU reported internal software error
628
555
ECU reported internal software error
Diagnostic fault check to report the accelerator pedal
629
555
position error
630
555
Diagnostic fault check to report the engine speed error
631
555
Error in the plausibility of the injection energizing time
632
555
Error in the plausibility of the start of energising angles
Diagnostic fault check to report the error due to non
633
555
plausibility in ZFC
Diagnosis fault check to report the demand for normal
634
555
mode due to an error in the PoI2 quantity
Diagnosis fault check to report the error to demand for an
635
555
ICO due to an error in the PoI2 shut-off
Descripción en Inglés
73

Publicidad

loading

Este manual también es adecuado para:

D 600 ap plusD 600 apgD 600 apg plus