D 600 AP / D 600 AP PLUS / D 600 APG / D 600 APG PLUS
Cuadro de averías motor Deutz
Código
Código
parpadeo
The standstill-regeneration mode time exceeds the long-
limit.
1882
8-4-5
Vehicle was too long or too often in standstill mode.
Make oil change and reset counter.
The standstill-regeneration mode time exceeds the short-
limit.
1883
8-4-5
Vehicle was too long or too often within a short time in
standstill mode.
Make oil change and reset counter.
1884
2-6-7
-
1889
2-6-9
Master / Slave Can disturbed.
1891
2-7-2
Inducement level 1 activ
1892
2-7-3
Inducement level 2 activ
The standstill-regeneration mode time exceeds the long
limit threshold.
1893
2-7-5
Vehicle was too long or too often in standstill mode.
Change oil and reset counter.
The standstill-regeneration mode time exceeds the short-
limit.
1894
2-7-6
Vehicle was too long or too often within a short time in
standstill mode. Change oil and reset counter.
1895
2-7-7
DEF tank temperature, temperature too high
1896
2-7-8
DEF quality sensor, short circuit to battery or open load
1897
2-7-8
DEF quality sensor, short circuit to ground
DEF quality sensor, internal temperature sensor short
1898
2-7-7
circuit to battery or open load
DEF quality sensor, internal temperature sensor short
1899
2-7-7
circuit to ground
1900
2-7-9
Standstill request due to crystalisation ignored too long
1901
2-8-3
Variant handling, address error
1902
2-8-3
Variant handling, Synchronisation error
DEF quality sensor, Significantly diluted DEF or another
1904
2-7-8
liqui than DEF in the tank.
DEF quality sensor, DEF quality cannot be measured
1905
2-7-8
within a certain time frame.
1907
2-7-8
Urea quality at UQS invalid
1908
2-7-7
Temperature at UQS invalid
1909
6-6-9
Urea Tank Temperature is above the warning threshold
DEF qualitysensor, tank level; DEF level out of physial
1910
1-2-9
range
1911
1-2-7
The DEF Level at UQS out of max. physical range
1912
1-2-7
Quality at UQS out of min. physical range
DEF qualitysensor, tank temperatur; Temperature out of
1913
6-6-9
physial range
DEF qualitysensor, tank temperatur; Short circuit to battery
1914
6-6-9
or open load
DEF qualitysensor, tank temperatur; Short circuit to
1915
6-6-9
ground
1917
2-8-6
Standstill request ignored too long.
Standstill time based escalation requests Inducement
1918
2-8-6
step 2
Intake Throttle Flap, H-Bridge, wiring harness broken at
1921
5-9-4
connected actuator
Intake Throttle Flap, H-Bridge, current above maximum
1922
5-9-4
threshold
Intake Throttle Flap, H-Bridge, short circuit to battery
1924
5-9-4
(A02)
Intake Throttle Flap, H-Bridge, short circuit to battery
1925
5-9-4
(A67)
Intake Throttle Flap, H-Bridge, short circuit to ground
1926
5-9-4
(A02)
Descripción en Inglés
Código
Código
parpadeo
Intake Throttle Flap, H-Bridge, short circuit to ground
1927
5-9-4
(A67)
Intake Throttle Flap, H-Bridge, position of actuator not
1931
5-9-4
plausible (deviation from setpoint more than 7%)
Intake Throttle Flap, H-Bridge, short circuit to battery
1935
5-9-4
oder broken wiring harness
1936
5-9-4
Intake Throttle Flap, H-Bridge, short circuit to ground
1943
3-1-3
SCR error code in master ECU active.
1944
3-1-3
DEF tank level failure is in master ECU active.
1945
3-1-3
SCR afterrun failure is in master ECU active.
1946
3-1-3
SCR Co2Off failure is in master ECU active.
1947
3-1-3
SCR disable DEF dosing failure is in master ECU active.
1971
3-1-5
Inducement HW Failure Slave.
1972
3-1-5
Inducement SCR Tamp. Slave
1973
3-1-5
Inducement DEF Qualitity in Slave ECU
1974
3-1-5
Urea Level Error Slave
1975
3-1-5
Urea Temp. Error Slave
1976
3-1-5
Urea Level Replace Slave
1977
3-1-5
SCR System Afterrun Slave
1978
3-1-5
Switch Off SCR System Slave
1979
3-1-5
Disable SCR Dosing Slave
1980
3-1-5
SCR regeneration failure is in slave ECU active.
1983
3-1-5
Urea CONC Replace Slave
1984
3-1-5
Urea Quality Error Slave
1989
3-1-5
NOX sensor downstream error in slave ECU
1990
3-1-5
DEF dosing valve error in slave ECU
1992
3-1-5
DEF pressure problems in slave ECU
1993
3-1-5
Reverting valve error in slave ECU
1994
3-1-5
DEF back flow line heater error on slave ECU
1995
3-1-5
Error NOx-Tailpipe emissions exceeded on Slave ECU
1996
3-1-5
DEF suction line heater error on slave ECU
1997
3-1-5
DEF supply module heater error on slave ECU
1998
3-1-5
Error Exhaust pressure upstream SCR on Slave ECU.
1999
3-1-5
Error Exhaust temperature upstream SCR on Slave ECU
2000
3-1-5
DEF pressure line heater error on slave ECU
2001
3-1-5
Error Urea pump temperature on Slave ECU
2002
3-1-5
Error DEF heater relais on Slave ECU.
2003
3-1-6
2007
2-8-7
Announcement triggers the Inducement Level 2
2008
8-4-5
Max. launch time for stand still exceeded (60min).
2011
6-6-8
Dynamic temperatur check of temp before SCR
Set together with DFC_SCRCoBldUpLoPres. DFC_
SCRCoBldUpLoPresRst is only used for inducement
2013
9-9-6
purposes.
It ensures that legal inducement is working correctly.
2014
2-7-8
Diluted DEF in the tank.
Descripción en Inglés
81