D 600 AP / D 600 AP PLUS / D 600 APG / D 600 APG PLUS
Cuadro de averías motor Deutz
Código
Código
parpadeo
Open time of Pressure Relief Valve (PRV) for wear out
833
2-5-3
monitoring had exceeded
834
7-6-1
Electrical fuel pre - supply pump; open load
Electrical fuel pre - supply pump. ECU powerstage over
835
7-6-1
temperature.
836
7-6-1
Electrical fuel pre - supply pump; short circuit to battery
837
7-6-1
Electrical fuel pre - supply pump. Short circuit to ground.
Pressure sensor upstream turbine, Physical Range Check
847
1-3-9
high.
Pressure sensor upstream turbine, Physical Range Check
848
1-3-9
low.
Pressure sensor upstream turbine, signal range check
849
1-4-1
(SRC) high.
Pressure sensor upstream turbine, signal range check
850
1-4-1
(SRC) low.
856
1-3-4
Rail pressure metering unit, Positive governor deviation.
Rail pressure metering unit, Rail pressure disrupted.
857
1-3-4
Maximum positive deviation of rail pressure exceeded.
Rail pressure metering unit, Rail pressure disrupted.
858
1-3-4
Maximum positive deviation of rail pressure in metering
unit exceeded (RailMeUn1).
Rail pressure metering unit, Rail pressure below the target
859
1-3-4
range .(RailMeUn2)
Railsystem leakage detected.(RailMeUn10)
Rail pressure metering unit, Minimum rail pressure
exceeded (RailMeUn3)
861
1-3-4
Negative deviation of rail pressure second stage
(RailMeUn22)
Rail pressure metering unit, Maximum rail pressure
862
1-3-4
exceeded.
Rail pressure metering unit, Setpoint of metering unit in
864
1-3-4
overrun mode not plausible.
865
1-3-4
Setpoint of metering unit in overrun mode not plausible
Rail pressure raw value is intermittent
874
1-4-7
No detail informationen!
rail pressure raw value is above maximum offset
875
1-4-7
No detail informationen!
876
1-4-6
Maximum rail pressure exceeded (PRV).
Sensor error rail pressure. Sensor voltage above upper
877
1-4-7
limit.
Sensor error rail pressure. Sensor voltage below lower
878
1-4-7
limit.
881
1-4-9
Longterm adaption factor below threshold
Nox conversion rate insufficient (SCR-Cat defect, bad
882
1-4-9
DEF quality)
Nox conversion rate insufficient (SCR-Cat defect, bad
883
1-4-9
DEF quality); temperature range 1
DFC for plausibility error Min for NOx sensor downstream
887
1-8-4
of SCR Cat.
DFC for plausibility error Max for NOx sensor upstream of
889
1-8-5
SCR Cat
892
2-3-6
Sensor backflow line pressure (SCR); plausibility error
SCR Monitoring; Pressure stabilisation error, general
893
8-7-1
pressure check error (SCR)
894
8-7-2
Pressure stabilisation error dosing valve (SCR)
897
8-7-5
Pump pressure SCR metering unit too high.
898
8-7-6
Pump pressure SCR metering unit too low
899
8-7-7
Pressure overload of SCR-System.
900
8-7-8
Pressure build-up error SCR-System.
903
8-8-1
DEF tank temperature too high.
Sensor SCR catalyst upstream temperature too high;
905
8-8-3
plausibility error.
Descripción en Inglés
Código
Código
parpadeo
908
8-8-6
DEF dosing valve blocked (SCR)
DEF supply module heater temperature; plausibility error
914
1-4-8
(normal condition).
Sensor DEF supply module heater temperature;
915
1-4-8
plausibility error (cold start condition)
Sensor DEF supply module temperature; plausibility error
916
6-8-9
(normal condition)
Sensor DEF supply module temperature; plausibility error
917
6-8-9
(cold start condition)
SCR plausibility, OBD and diagnosis; Stuck in range
918
2-4-3
check of DEF tank temperature sensor DEF-tank without
heating function (heating phase)
919
1-3-1
Immobilizer status; fuel blocked
DFC to block the fuel by Sia
920
1-3-1
No detail informationen!
DFC to indicate that TEN-code or UC-code received if
921
1-3-1
ECU is learned.
No detail informationen!
DFC to indicate that no code is received via CAN. No
922
1-3-1
detail informationen!
DFC to indicate that wrong code is received.
923
1-3-1
No detail informationen!
DEF supply module heater temperature; duty cycle in
925
1-4-8
failure range.
DEF supply module heater temperature; duty cycle in
926
1-4-8
invalid range.
Urea supply module temperature measurement not
927
6-8-9
available.
DEF supply module PWM signal; period outside valid
928
6-9-1
range.
929
6-9-1
Detect faulty PWM signal from Supply Modul.
DEF supply module temperature; duty cycle in failure
930
6-8-9
range.
Urea supply module temperature; duty cycle in invalid
931
6-8-9
range.
932
1-2-6
Handthrottle idle validation switch; short circuit to battery
935
2-2-6
Sensor error accelerator pedal. signal range check high.
937
1-2-6
Handthrottle; short circuit to ground
940
2-2-6
Sensor error accelerator pedal. Signal is below the range.
Sensor error burner temperature; signal range check
942
7-1-4
high
943
1-2-7
Sensor error DEF tank level; signal range check high
944
7-1-4
Sensor error burner temperature; signal range check low
945
1-2-7
Sensor error DEF tank level; signal range check low
946
2-8-2
Failure of sensor supply voltage 1.
947
2-8-2
Failure of sensor supply voltage 2.
948
2-8-2
Failure of sensor supply voltage 3.
956
5-1-2
Starter relay high side. Short circuit to battery.
957
5-1-2
Starter relay high side short circuit to ground.
958
5-1-2
Starter relay low side no load error.
959
5-1-2
Starter relay powerstage over temperature.
960
5-1-2
Starter relay low side short circuit to battery.
961
5-1-2
Starter relay low side short circuit to ground.
965
7-1-5
Burner shut of valve; short circuit to battery
969
5-1-3
SVS lamp; open load
970
5-1-3
SVS lamp: powerstage over temperature
971
5-1-3
SVS lamp; short circuit to battery
972
5-1-3
SVS lamp; short circuit to ground
973
5-5-5
Softwarereset CPU SWReset_0
974
5-5-5
Softwarereset CPU SWReset_1
Descripción en Inglés
75