D 600 AP / D 600 AP PLUS / D 600 APG / D 600 APG PLUS
Cuadro de averías motor Deutz
Código
Código
parpadeo
Master ECU and Slave ECU have been identified as the
1484
8-9-5
same types
Master ECU and Slave ECU data sets or software are
1485
8-3-6
not identical
1486
6-7-6
SCR mainrelay; open load (only CV56B)
SCR mainrelay; short circuit to battery
1488
6-7-6
(only CV56B)
SCR mainrelay; short circuit to ground
1489
6-7-6
(only CV56B)
1490
6-6-7
SCR reverting valve; open load
1491
6-6-7
SCR reverting valve; over temperature
1493
6-6-7
e SCR reverting valve; short circuit to ground
1505
8-4-3
Fuel low pressure pump; error pressure build up
Exhaust Gas Recirculation AGS Sensor; signal not
1523
8-2-2
plausible
Exhaust Gas Recirculation AGS Sensor; Sensed exhaust
1524
8-2-2
mass value above maximum physical value
Exhaust Gas Recirculation AGS Sensor; Sensed exhaust
1525
8-2-2
mass value below miniimum physical value
Exhaust Gas Recirculation AGS Sensor; plausibility error,
1526
8-2-2
AGS sensor has not passed the burn off process
Exhaust Gas Recirculation AGS Sensor; Temperature of
1527
8-2-2
EGR mass not plausible
(Upstream NOx-Sensor) Diagnostic Fault Check for
invalid upstream NOx value (Sensor self diagnostic DFC
1529
8-9-7
set by Deutz-SW)
NOx-Sensor before SCR-Cat: Invalid upstream NOx value
(Downstream NOx-Sensor) Diagnostic Fault Check for
1530
8-9-8
invalid downstream lambda value (Sensor self diagnostic
DFC set by Deutz-SW)
(Upstream NOx-Sensor) Diagnostic Fault Check for
1531
8-9-9
invalid upstream lambda value (Sensor self diagnostic
DFC set by Deutz-SW)
(Downstream NOx-Sensor) Diagnostic Fault Check for
1532
2-4-5
invalid downstream NOx value (Sensor self diagnostic
DFC set by Deutz-SW)
NOx sensor downstream SCR-CAT, sensor internally
1533
2-4-6
open load
NOx sensor downstream SCR-CAT, sensor internally
1534
2-4-7
short circuit
NOx sensor upstream SCR-CAT, sensor internally open
1535
2-4-8
line
NOx sensor upstream SCR-CAT, sensor internally short
1536
2-4-9
circuit
NOx sensor downstream SCR-CAT, lambda value above
1537
2-5-5
upper physical threshold
NOx sensor downstream SCR-CAT, lambda value below
1538
2-5-6
lower physical threshold
NOx sensor upstream SCR-CAT, lambda value above
1539
2-5-7
upper physical threshold
NOx sensor upstream SCR-CAT, lambda value below
1540
2-5-8
lower physical threshold
(Downstream NOx-Sensor) Diagnostic Fault Check for
1541
2-5-9
downstream NOx value over maximum limit (DFC set by
Deutz-SW)
NOx-Sensor downstream SCR-CAT, NOx value below
1542
2-6-1
minimum value.
NOx-Sensor upstream SCR-CAT, NOx value above
1543
9-1-1
maximum value.
NOx sensor upstream SCR-CAT, NOx value below lower
1544
9-1-2
physical threshold
Plausibility error between pressure downstream turbine
1545
9-6-8
(PTrbnDs) and ambient air pressure (EnvP)
Descripción en Inglés
Código
Código
parpadeo
Relay Urea backflow line heater: broken wiring detected
(open load) in-line engine: SCR-backflow line (K29)
1555
8-6-9
V-engine:
Slave: SCR-suction / backflow line (K32.2)
1556
8-6-9
SCR main relay not connected
1557
8-6-9
SCR heater pressureline; open load
1558
8-6-9
SCR heater mainrelay; short circuit to battery
SCR heater main relay load side (K31) on heating valve
1559
8-6-9
(Y31),
Short cut to ground.
Relay Urea suction line: broken wiring detected (open
load) Row engine: SCR suction line (K28)
1560
8-6-9
V-engine: Master: common SCR-suction line (K28) Slave:
commoon SCR backflow line (K29)
1561
8-6-9
SCR heater supply module; open load
1562
8-6-9
SCR heater tank; open load
Pressure sensor upstream SCR-CAT, pressure above
1565
8-9-2
upper physical threshold
Pressure sensor upstream SCR-CAT, pressure below
1566
8-9-2
lower physical threshold
Pressure sensor upstream SCR-CAT; short circuit battery
1569
8-9-2
or open load
1570
8-9-2
Pressure sensor upstream SCR-CAT; short circuit ground
SCR measurement heater output stage; short circuit
1579
8-9-3
battery or open load
DEF supply module, heater temperature above upper
1581
8-9-4
physical threshold
DEF supply module, heater temperature below lower
1582
8-9-4
physical threshold
DEF supply module, temperature above upper physical
1585
8-9-4
threshold
DEF supply module, temperature below lower physical
1586
8-9-4
threshold
1593
1-2-9
DEF tank, DEF level above upper physical threshold
1594
1-2-9
DEF tank, DEF level below lower physical threshold
1597
9-6-8
Pressure downstream turbine, plausibility error
1598
8-9-2
Pressure sensor upstream SCR-CAT, plausibility error
Passive regeneration of DPF; DOC error
1617
8-1-8
Temperature sensor us. and ds. DOC simultaneously
defect
1619
8-8-4
Urea Error Lamp; open load
1620
8-8-4
Urea Error Lamp; temperatur over limit
1621
8-8-4
Urea Error Lamp; short circuit battery
1622
8-8-4
Urea Error Lamp; short circuit ground
Fuel low pressure upstream fuel low pressure pump not
1630
9-5-5
plausible
Fuel low pressure upstream fuel low pressure pump,
1631
9-5-5
pressure above maximum warning threshold
Fuel low pressure upstream fuel low pressure pump,
1632
9-5-5
pressure above maximum shut off threshold
Fuel low pressure upstream fuel low pressure pump,
1633
9-5-5
pressure below minimum shut off threshold
Fuel low pressure upstream fuel low pressure pump,
1634
9-5-5
pressure below minimum warning threshold
Maximum standstill time reached; oil exchange request
1635
8-1-8
ignored
1639
9-6-6
SCR System,pressure build up not possible
1646
8-6-9
DEF supply modul, time for defrosting too long
1647
8-6-9
DEF tank, time for defrosting too long
Urea Tank Signal to HMI for indicating the Urea Tank-Level
1654
1-3-8
(Urea tank volume ratio low threshold 1)
Descripción en Inglés
Master: SCR-suction / backflow line (K32.1)
79