78
Cuadro de averías motor Deutz
Código
Código
parpadeo
Burner Control; Fuel line ShutOff downstream - broken
1263
8-6-4
Burner fuel line pipe leak behind Shut Off Valve
1264
8-5-5
Burner Shut Off Valve; blocked open
Timeout error of CAN-Receive-Frame
1285
8-2-4
ComMS_Sys1TO (error memory Slave);
Master-Slave internal CAN message
Timeout error of CAN-Receive-Frame
1286
8-2-5
ComMS_Sys2TO (error memory Slave);
Master-Slave internal CAN message
Timeout error of CAN-Receive-Frame
1287
8-2-6
ComMS_Sys3TO (error memory Slave);
Master-Slave internal CAN message
Timeout error of CAN-Receive-Frame
1288
8-2-7
ComMS_Sys4TO (error memory Slave);
Master-Slave internal CAN message
Timeout error of CAN-Receive-Frame
1289
8-2-8
ComMS_Sys5TO (error memory Slave);
Master-Slave internal CAN message
Timeout error of CAN-Receive-Frame
1290
8-2-9
ComMS_Sys6TO (error memory Slave);
Master-Slave internal CAN message
Master Slave, Error of message counter CAN receive
1291
8-3-1
message ComMSMoFOvR; ComMSMoFOvR1CNT
Master-Slave CAN; Error Checksum of
1292
8-3-2
CAN-Receive Message
Master-Slave CAN; Error of message length
1293
8-3-3
of CAN receive message ComMSMoFOvR;_
ComMSMoFOvR1DLC
Timeout error CAN message ComMSMoFOvR1TO error
1294
8-3-4
memory Slave
1299
6-5-5
Wastegate plauisibility error off CAN transmit message.
Timeout Error of CAN-Receive-Frame ComTrbChActr;
1300
6-5-5
Wastegate
Deviation of the exhaust gas temperature setpoint to
1302
8-6-6
actual value downstream (DOC) too high
Check of missing injector adjustment value programming
1324
7-9-5
(IMA) injector 7 (in firing order)
check of missing injector adjustment value programming
1325
7-9-6
(IMA) injector 8 (in firing order)
1326
7-9-7
Injector cylinder bank 1 slave; short circuit
1327
7-9-8
Injector cylinder bank 2 slave; short circuit
1328
7-9-9
Injector powerstage output Slave defect
Injector 7 (in firing order); interruption of electric
1329
1-7-7
connection
Injector 8 (in firing order); interruption of electric
1330
1-7-8
connection
1333
1-7-7
Injector 7 (in firing order); short circuit
1334
1-7-8
Injector 8 (in firing order); short circuit
Timeout of Short-Circuit Ground Diagnosis Cyl. Bank
1337
5-6-5
0;_IVDiaShCirGndToutBnk_0
Timeout of Short-Circuit Ground Diagnosis Cyl. Bank
1338
5-6-6
1;_IVDiaShCirGndToutBnk_1
1339
5-6-5
Injector diagnostic; Short circuit to ground cylinder bank 0
1340
5-6-6
Injector diagnostic; Short circuit to ground cylinder bank 1
Injector diagnostics; time out error in the SPI
1341
5-5-5
communication
Injector diagnostics Slave; time out error in the SPI
1342
5-5-5
communication
Timeout Error of CAN-Receive-Frame MSMon_FidFCCTO;
1345
8-9-6
Master-Slave CAN communication faulty
Error memory Slave reports FID MSMonFC2 (collective
1357
8-3-6
error)
Descripción en Inglés
D 600 AP / D 600 AP PLUS / D 600 APG / D 600 APG PLUS
Código
Código
parpadeo
Error memory Slave reports FID MSMonFC3 (collective
1368
8-3-6
error)
1378
6-9-4
Sensor air pump airpressure; plausibility error
Sensor exhaust gas back pressure burner; plausibility
1379
7-1-6
error
1380
6-9-2
Sensor differential pressure (DPF); plausibility error
1381
8-3-9
Rail pressure safety function is not executed correctly ()
1389
7-1-5
Burner Shut Off Valve; open load
1390
7-1-5
Burner Shut Off Valve; powerstage over temperature
1392
7-1-5
Burner Shut Off Valve; short circuit to ground
Burner temperature sensor; Plausibility Check for burner
1395
7-1-4
temperature sensor
Sensor burner temperature; plausibility error
1398
6-8-1
Physical range check high for ECU temperature
Sensor exhaust gas temperature OxiCat downstream
1402
6-8-4
(normal operation); plausibility error
Sensor exhaust gas temperature OxiCat downstream
1403
6-8-4
(regeneration); plausibility error
1411
8-1-4
Wastegate actuator; internal error
Wastegate actuator; EOL calibration not performed
1412
8-1-4
correctly
Wastegate actuator calibration deviation too large,
1413
8-1-4
recalibration required
1414
8-1-4
Wastegate; status message from ECU missing
1415
8-1-4
Wastegate actuator; blocked
1417
8-1-4
Wastegate actuator; over temperature (> 135°C)
1418
8-1-4
Wastegate actuator; operating voltage error
Warning threshold for an internal actuator error exceeded,
1423
5-9-4
< 4L EGR.actuator und >4L Air Intake Flap
Shut off threshold for an internal actuator error exceeded,
1424
5-9-4
< 4L EGR.actuator und >4L Air Intake Flap
air temperature within air filter box above maximum
1425
2-2-6
physical value
1431
8-1-5
CAN message PROEGRActr; plausibility error
Timeout Error of CAN-Receive-Frame ComEGRActr -
1432
8-1-5
exhaust gas recirculation positioner
1436
8-1-6
Disc Separator; open load
1437
8-1-6
Disc Separator; powerstage over temperature
1438
8-1-6
Disc separator; short circuit to battery
1439
8-1-6
Disc separator; short circuit to ground
1440
8-1-5
EGR actuator; internal error
1441
8-1-5
EGR actuator, calibration error
1442
8-1-5
EGR actuator; status message "EGRCust" is missing
1443
8-1-5
EGR actuator; due to overload in Save Mode
Temperature during stand-still main phase too low or too
1455
7-1-1
high
High exhaust gas temperature EGR cooler downstream;
1458
7-7-1
warning threshold exceeded.
1464
-
1466
-
1467
-
1469
-
1470
-
1471
-
1472
-
1481
8-4-5
DPF system; operating voltage error
1482
1-8-8
CAN message ComMS_Sys7 not received from slave
Descripción en Inglés