Table 5
Terminals
Function
1 - 2
Flash
3
S2 Photo
4
Phototest
5
Start
6
Stop
7
0 VDC
8
24 VDC
9
S1 Edge
10
24 VDC
L - N
Alimentazione
13 - 14
Antenna
m
TIMER FUNCTION: if START contact is kept closed
(for instance through a timer-controlled or bistable relay),
control unit opens the door and leaves the door opened.
The automation does not accept closing commands (neither
automatic nor wired) until START contact is reopened.
In this mode, dip switch 1 STEP is set to OFF and dip 2 AUTO
to ON to ensure that the gate never remains locked open.
m
If START contact is kept closed during the control unit
starting after a blackout, the door will immediately execute
the start command.
3.6 - CONNECTING ROLLS TO THE MAINS
m
CAUTION!
- Never cut or remove the cable supplied with ROLLS.
-If not already available, create a power outlet for ROLLS.
This operation must be performed by qualified and
experienced personnel in strict compliance with the current
legislation, regulations and standards.
ROLLS must be connected to the supply mains by a qualified
electrician.
To test ROLLS, just insert the plug into a power outlet, using an
extension if necessary (fig. 29).
29
Description
24Vdc max. 15W warning light
Input for safety devices, normally
closed contact. Function
associated to dip switch Func
24Vdc output for safety
test
Start, normally open contact
Stop, normally closed contact
Negative terminal for
accessories devices connected
Power supply 24Vdc
Input for safety edges, normally
closed contact. Brief movement
inversion in case of obstacle
during closing and block of the
movement during opening
Power supply 24Vdc
Power supply 230V ac
Antenna ground (13)
Antenna signal (14)
3.7 - ELECTRONIC CONTROL UNIT
The following figure (fig. 30) the buttons (A), LEDs (B), trimmers
(C) and dip switches (D), which are used for the various
configurations, are identified inside the electronic board.
30
C
A B
D
ON
1
2
3
4
ENGLISH - 31 -