"S1 Edge" OPENING/CLOSING PHASE SAFETY DEVICES
It is possible to connect devices (e.g. photocells or edges) with
normally closed (NC) contact or 8K2 resistive edges to the "S1
Edge" input (terminal 9-10).
The factory wire bridge connected to PHO2 must be removed
when using this input.
These devices intervene while the door is moving, in particular:
-
with the door closed they stop the opening commands.
-
with the door open they stop the closing commands.
-
during the closing phase they command a brief inversion
-
during the opening phase they stop movement
m
When multiple devices are connected on this contact,
they must be series connected.
m
If more photocell pairs are connected, RX and TX units
of the safety set should be cross installed.
10.4 - 24 VDC ACCESSORIES' POWER
SUPPLY
TERMINALS: 8-7, 10-7
Nominal voltage 24 VDC , max. 250mA, output for powering
external accessories like photocells, radio receivers, etc.
Real voltage output can be greater than nominal value, check the
compatibility of external accessories.
10.5 - WIRED COMMANDS
TERMINALS: 5-6-8-10
Inputs for starting and stopping the motor via wired commands.
START CONTACT
The "START" input (terminals 5-8) is a normally open gate
activation command by wire. The activation method is set up by
dip switches 1 and 2 - see Paragraph 4.1.
This input is a voltage free (dry contact) only.
Connecting power to this input will void warranty.
m
TIMER FUNCTION: if START contact is kept closed
(for instance through a timer-controlled or bistable relay),
control unit opens the gate and leaves the gate opened.
The automation does not accept closing commands (neither
automatic nor wired) until START contact is reopened. In
this mode, dip switch 1 STEP is set to OFF and dip 2 AUTO
to ON to ensure that the gate never remains locked open.
m
If multiple START contacts are connected, connect the
contacts in parallel.
m
If START contact is kept closed during the control unit
starting after a blackout, the gate will immediately execute
the start command.
STOP CONTACT
The "STOP" input (terminal 6) is for stopping and locking any
movement of the gate immediately. This input is a normally closed
and voltage free (dry contact) only.
Connecting power to this input will void warranty. To restore
operation this contact must be closed.
10.6 - ANTENNA
TERMINALS: 13-14
TAntenna terminal for transmitter signal reception.
A wire is factory connected to this terminal.
For extending the reception range, an external antenna can be
connected (present in the King Gates flashing lights range).
If an external antenna is connected, the wire connected in series
must be disconnected.