4. CONTROL UNIT SETTING
4.1 - DIP-SWITCH ADJUSTMENT
DIP
DIP status
DIP 1 STEP
1-ON
2-OFF
DIP 2 AUTO
1-ON
2-ON
1-OFF
2-ON
1-OFF
2-OFF
DIP 3
ON
CHECK
OFF
DIP 4
ON
FUNCTION
OFF
DIP1 "STEP":
If the dip-switch is put to ON, the step-by-step operating mode
is activated. At every start pulse (wired or via transmitter),
the control unit performs an action. Starts the motor if the
automation system is stopped, and stops it if it is moving.
If the STEP dip-switch is put to OFF, the OPEN FULLY/PAUSE/
CLOSE FULLY/STOP operating mode is activated (apartment block).
The control unit only accepts commands (either wired or via
transmitter) for the opening phase. With the automation in the
opening phase, it continues to open, and with the system in the
closing phase it reopens fully. The automation can re-close with
the time set through the "PAUSE" potentiometer, if the "AUTO"
dip-switch is set to ON.
If not, it is necessary to give a START command (either wired or via
transmitter) with the automation fully open.
DIP2 "AUTO":
If the dip-switch is put to ON, the automatic re-closing function is
activated.
The control unit automatically closes the leaves after the time set
through the "PAUSE" potentiometer (see Paragraph 4.2).
If the "AUTO" dip-switch is put to OFF, the automatic re-closing
function is deactivated.
To close the leaves, therefore, a command must be given (either
wired or via transmitter).
DIP3 "CHECK":
If the dip-switch is put to ON, the safety devices connected to
terminal "Phototest" [4] are subject to a preventive check before
starting any movement.
If the "CHECK" dip-switch is put to OFF, the safety devices
connected to terminal "Phototest" [4] are constantly supplied.
- 32 - ENGLISH
Description of operation
Step-by-step command mode:
Open / Stop / Close / Stop
Step-by-step with automatic
closing (time set with the
"Pause" knob)
Opening only command
mode with automatic closing
(condominium function)
Open / Close / Open command
mode (no Stop)
Test of the safety devices
connected to terminal [4]
"Phototest" enabled after
learning the new stroke
Test of the safety devices
connected to terminal [4]
"Phototest" disabled
Devices connected to "S2
Photo" terminal [3] intervene by
stopping the movement both in
opening and closing phases
Devices connected to "S2
Photo" terminal [3] intervene
just during closing phase with
immediate inversion
DIP4 "FUNCTION":
If the dip-switch is put to ON, the safety devices connected to "S2
Photo" terminal [3] intervene by stopping the movement during
both the opening and closing phases. If the dip-switch is put to
OFF, the safety devices connected to "S2 Photo" terminal [3]
intervene just during the closing phase with immediate inversion.
4.2 - POTENTIOMETER ADJUSTMENT
FORCE
Power: adjustment of motor power. Turning the knob clockwise
increases the motor's power and speed. To validate the
modification, it is necessary to programme the gate path.
OBSTACLE
Obstacle, sensitivity to obstacles: adjustment of the obstacle
detection function. Turning the knob clockwise increases the
drive time before obstacle detection (less sensitivity). Therefore,
in systems with particularly unfavorable mechanical conditions, it
is advisable to keep the drive time high. OBSTACLE is set at half
position (50%) as factory setup.
PAUSE
Pause time before automatic gate closing. Turning the knob
clockwise increases the pause time from 0 to 180 seconds.
Please note: this knob is functional only when AUTO dip-switch is
put to ON.
m
The variation of the "FORCE" potentiometer requires
repeating the programming of the door path (par. 6).
5 - TRANSMITTER (REMOTE CONTROL
UNIT) PROGRAMMING
m
If, at the start of the following procedures, the
"set", "radio" and "error" LEDs flash, it means that the
programming protections have been activated – see
Paragraph 15.
Therefore, radio transmitters learning is not possible.
m
To interrupt the following programming procedures at
any time, press the RADIO button or wait 20 seconds.
5.1 - START BUTTON PROGRAMMING
This procedure allows for programming the button of the radio
control linked to the automation's start function:
1. PRESS THE RADIO BUTTON FOR 1 SECOND: The red "radio"
LED turns on in the fixed mode (if not, consult Paragraph 15)
2. PRESS THE DESIRED BUTTON ON EVERY TRANSMITTER TO BE
PROGRAMMED: The red "radio" LED flashes
3. PRESS TRHE RADIO BUTTON UNTIL RADIO LED TURNS OFFOR
WAIT 20 SECONDS TO EXIT THE PROCEDURE: The red "radio"
LED turns off