6 - PROGRAMMING THE DOOR PATH
To start up the system, one of the following programming
procedures must be carried out:
basic programming of the automation's movement: self-
learning of the manoeuvre times and slowdown start points.
advanced programming of the automation's movement: self-
learning of the manoeuvre times and manual setting of the
slowdown start points.
m
ATTENTION: before starting one of the following
procedures for programming the door route, make sure that
all the safety devices are correctly connected.
If not connected they must be jumpered with the common
one.
m
If, at the start of the following procedures, the
"set", "radio" and "error" LEDs flash, it means that
the programming protection has been activated – see
Paragraph 15. Consequently, the memorization of the
transmitters is not possible.
m
To interrupt the following programming sequences at
any time, press the SET and RADIO buttons simultaneously.
6.1 - BASIC PROGRAMMING OF THE
AUTOMATION'S MOVEMENT
Through this procedure, the control unit memorizes working times
and power required for opening and closing the system.
The slowdown points are automatically set to ensure a correct
arrival to the end of gate path.
For excluding slowdown, see paragraph 6.2.
1. PUT THE DOOR TO HALF WAY POSITION
2. PRESS THE SET BUTTON FOR 3 SECONDS: The yellow "set"
LED flashes and then turns on in fixed mode
3. THE DOOR PERFORMS A PARTIAL OPENING MOVEMENT: The
yellow "set" LED stays on in fixed mode
4. THE DOOR PERFORMS A FULL CLOSING MOVEMENT
5. THE DOOR PERFORMS A FULL OPENING MOVEMENT
6. THE DOOR PERFORMS A FULL CLOSING MOVEMENT
7. THE DOOR PERFORMS A FULL OPENING MOVEMENT WITH
SLOWDOWNS: The yellow "set" LED turns off
8. THE DOOR PERFORMS A FULL CLOSING MOVEMENT WITH
SLOWDOWNS
9. END OF THE PROGRAMMING PROCEDURE
m
If the "FORCE" potentiometer is adjusted, the
automation's movement must be reprogrammed.
m
The red "Error" LED flashes during the automation's
movement when a mechanical stress point is detected (this
corresponds to increased motor effort). Adjust OBSTACLE
and FORCE knobs (slightly turn them clockwise) to solve
this and check gate mechanics if necessary.
- 34 - ENGLISH
6.2 - ADVANCED PROGRAMMING OF THE
AUTOMATION'S MOVEMENT
With this procedure, the control unit memorizes the times and
power required for opening and closing the system.
Moreover, this procedure allows for setting start point of
slowdowns or their deletion.
1. PUT THE DOOR TO HALF WAY POSITION
2. PRESS THE SET BUTTON FOR 2 SECONDS: The yellow "set"
LED flashes (if not, refer to Paragraph 15)
3. PRESS THE RADIO BUTTON FOR 1 SECOND: The yellow "set"
LED turns on in fixed mode
4. THE DOOR PARTIALLY OPENS: The yellow "set" LED stays on
5. THE DOOR MOVES TO FULL CLOSING POSITION: The yellow
"set" LED flashes
6. PRESS THE SET BUTTON OR A BUTTON OF A PROGRAMMED
TRANSMITTER OR CLOSE THE WIRED START CONTACT: The
yellow "set" LED stays on
7. THE DOOR PERFORMS THE OPENING OVEMENT
8. PRESS THE SET BUTTON OR A BUTTON OF A PROGRAMMED
TRANSMITTER OR CLOSE THE WIRED START CONTACT
TO SET THE SLOWDOWN START POINT (*), TO HAVE NO
SLOWDOWN, WAIT FOR THE MOVEMENT TO BE COMPLETED
9. THE DOOR COMPLETES THE OPENING PHASE
10. PRESS THE SET BUTTON OR A BUTTON OF A PROGRAMMED
TRANSMITTER OR CLOSE THE WIRED START CONTACT
11. THE DOOR PERFORMS A FULL CLOSING MOVEMENT
12. DURING MOVEMENT: PRESS THE SET BUTTON OR A BUTTON
OF A PROGRAMMED TRANSMITTER OR CLOSE THE WIRED
START CONTACT TO SET THE SLOWDOWN START POINT (*),
TO HAVE NO SLOWDOWN, WAIT FOR THE MOVEMENT TO BE
COMPLETED
13. THE DOOR COMPLETES THE CLOSING PHASE: The yellow
"set" LED turns off
14. END OF THE PROGRAMMING PROCEDURE: The LEDs return to
the normal operation configuration
(*) Minimum slowdown time must be 3 seconds.
m
If the "FORCE" potentiometer is adjusted, the
automation's movement must be reprogrammed.
m
The red "Error" LED flashes during the automation's
movement when a mechanical stress point is detected (this
corresponds to increased motor effort).
Adjust OBSTACLE Adjust OBSTACLE and FORCE knobs
(slightly turn them clockwise) to solve this and check gate
mechanics if necessary.