7 - TESTING AND COMMISSIONING
Once the programming setup has been completed, verify that:
•
the motors turn off after a few seconds once the opening or
closing phases end (the "error" LED turns off too);
•
the control unit responds to the connected wired commands:
"START" (terminal 5), and "STOP" (terminal 6);
•
all programmed radio transmitters are operational;
•
the safety devices connected to "S2 Photo" (terminal 3)
intervene while the door closes and prevent the open door
from closing;
•
the safety devices connected to "S1 Edge" (terminal 9)
intervene while the door opens and closes with a brief
movement inversion;
If the "Func" dip-switch is put to ON, check that S2 Photo safety
devices intervene also when the door opens and that they prevent
the closed door from opening.
8 - LED INDICATION
With the control unit powered up (if control unit protection is not
activated) the yellow "Set" led flashes briefly and, if everything
is correctly connected, the red "Stop" and "SIC" LEDs turn on to
indicate that the three safety contacts are closed circuits.
The yellow "Set" LED is reserved only for programming.
8.1 - INPUT STATUS LED INDICATION
SIC LED:
-
GREEN: contact S1 Edge (terminal 9) closed and S2 Photo
(terminal 3) open
-
RED: contact S1 Edge open and S2 Photo closed
-
YELLOW: contacts S1 Edge and S2 Photo both closed
-
OFF: contacts S1 Edge and S2 Photo both open
RED START LED:
-
ON in fixed mode if the Start contact (terminals 5-8) is closed
-
OFF if the Start contact (terminals 5-8) is open
RED STOP LED:
-
ON in fixed mode if the Stop contact (terminals 6-8) is closed
-
OFF if the Stop contact (terminals 6-8) is opened
YELLOW SET LED:
-
is on in fixed mode or flashes when the control unit is in a
programming menu
-
is off when the control unit is in out of a programming menu
RED RADIO LED:
-
flashes when a command is received through King Gates
transmitter
-
is on in fixed mode when the control unit is in a radio
programming menu
-
is off when the control unit is in standby mode
RED ERROR LED:
- see paragraph 8.2
RED START LED, RED RADIO LED AND YELLOW SET LED:
-
If, when attempting to enter any programming scheme, the
"Set", "Radio" and "Error" LEDs flash fast three times, it
means that the "control unit protection" is activated. See
Paragraph 15 for solving the problem.
8.2 - ERROR STATUS LED
RED "ERROR" LED:
The red "error" LED has two functions:
-
During the automation's movement, the LED flashes when
a mechanical stress point is detected (this corresponds to
increased motor effort). Adjust FORCE and OBS knobs (slightly
turn them clockwise) to solve this and check gate mechanics if
necessary.
Attention: a minimum flash of this LED during the door
movement can be considered as normal.
-
In standby mode, the LEDs shows the current error type with a
series of regular flashes according to the following scheme:
Number of
Error description
flashes per
series
1
On-board memory fault
2
Photo-test of safety devices failed. See
Paragraph 4.1 for solving the problem
3
Automation's movement programming
required. See Paragraph 6
4
Input "S1 Edge" set as a resistive edge and
check failed. See Paragraph 13.4 for solving the
problem
5
Power limit threshold
6
Obstacle detection due to encoder
7
Obstacle detection due to current
ENGLISH - 35 -