13.2 - SELECTION OF THE AUX OUTPUT
OPERATING MODE
1. PRESS THE START BUTTON FOR 3 SECONDS: all the LEDs
switch off (if not, see paragraph 15)
2. PRESS THE RADIO BUTTON FOR 1 SECOND
•
If the yellow "Set" LED is on,
AUX = Electric lock (if the setting is correct, go to point 4,
if not, go to point 3)
OR
•
If the red "Error" LED is on in fixed mode,
AUX = courtesy light (if the setting is correct, go to point
4; otherwise, proceed to point 3)
3. PRESS THE RADIO BUTTON FOR 1 SECOND: the red "radio"
LED lights up in fixed mode and the "Error" and "Set" LEDs
light up according to the selected function
4. Press the SET and RADIO buttons at the same time or wait 10
seconds to exit the procedure: the LEDs return to the normal
operating configuration
14 - SELECTING THE TYPE OF DEVICES
CONNECTED TO "S1 EDGE"
DEFAULT = output for devices with normally closed contact
(terminal 9)
This procedure allows you to set the "S1 Edge" output for
managing the 8.2 kOhm resistive edges.
The control unit constantly checks the integrity of the coast by
measuring the resistance between the two dedicated terminals.
1. Press the START key for 3 seconds: all the LEDs switch off (if
not, see paragraph 15)
2. Press the START key for 1 second:
•
if the yellow "Set" LED is on "S1 Edge" = resistive edge (if
the setting is correct, go to point 4, if not, go to point 3)
OR
•
If the yellow "set" LED is off "S1 Edge" = device with
normally closed contact (NC)
(if the setting is correct, go to point 4; otherwise, proceed
to point 3)
3. Press the START key for 1 second: the red "error" LED turns
on in fixed mode and the "Set" LED turns on / off according
to the selected function
4. Press the SET and RADIO buttons at the same time or wait 10
seconds to exit the procedure: the LEDs return to the normal
operating configuration
m
In order to carry out the check on the safety devices,
the connected edges must be of the resistive type with 8.2
kOhm.
15 - ACTIVATING/DEACTIVATING THE
CONTROL UNIT PROTECTION DEVICE
DEFAULT = control panel protection not active
This function allows you to lock all the programming sequences
of the control unit and the settings that can be adjusted using the
trimmers.
To carry out a new programming sequence or to make a dip-
switch / trimmer modification effective, the protection must be
deactivated.
1. Press the START key for 3 seconds: all the LEDs switch off (if
not, see paragraph 15)
2. Press both START and RADIO buttons for 1 second
•
If the yellow "set" LED and the red "radio" LED are on:
central lock = activated (if the setting is correct, go to
point 4, if not, go to point 3)
OR
•
If the yellow "set" LED and the red "radio" LED are off:
central lock = disabled
3. Press both the START and RADIO buttons for 2 seconds: the
"set" and "radio" LEDs turn on / off according to the selected
function
4. Press the SET and RADIO buttons at the same time or wait 10
seconds to exit the procedure: the LEDs return to the normal
operating configuration
ENGLISH - 39 -