3.6 - ELECTRICAL CONNECTIONS OF SAFETY DEVICES
If EDGE, PH2, PH1 and STOP contacts are not used, they must be
disabled using the DIP-SWITCH selector.
This operation is possible by placing the corresponding selector in
the ON position.
# TERMINAL
18
11
12
13
STOP button
When it intervenes it completely stops the automation and prevents any automated or user command.
PHOTOCELL input PH1
During the closing movement, it stops the movement of the automation and performs a reversal until the gate reaches the OPEN
GATE position.
Refer to the advanced parameters to configure the behavior of the photocell input.
PHOTOCELL input PH2
During the opening movement, temporarily stops the motion for as long as the photocell is engaged.
During this phase the blinker cyclically performs 3 flashes.
Once restored the contact resumes movement in the direction of opening.
Refer to the advanced parameters to configure the behavior of the photocell input.
18
11
COM
12 - English - Translated from the original language
FUNCTION
COMMON CONTACT
PHOTOCELL INPUT PH2
PHOTOCELL INPUT PH1
STOP
12
13
NOTE
Connect a clean contact (voltage free) Normally
Closed.
Signal LED Normally On.
STOP BUTTON
PHOTOCELL INPUT PH1
PHOTOCELL INPUT PH2
DESCRIPTION
6-1622467M - rev. 0 - 07/03/2024