Type of security edge installed
Select the type of safety edge connected to the EDGE input.
PARAMETER
Edm
Mode of intervention EDGE input
Customize the behavior of the control unit following the intervention of the device connected to the EDGE input.
Value 0: Only during the closing movement, performs a reversal of motion until reaching the position of "OPEN GATE".
Value 1: During any movement, it stops the automation and then a short reversal to free the obstacle.
PARAMETER
iEd
Slowdown ramp on EDGE input intervention
It determines how long the gear motor stops its movement following the stop caused by the intervention of the EDGE input.
PARAMETER
ebt
Reversal time on EDGE input intervention
Determines how long the gear motor performs the movement in the opposite direction following the stop caused by the intervention
of the EDGE input (only with IED = 1).
PARAMETER
ert
28 - English - Translated from the original language
+24V
+24V
GND
TEST
6
7
8
9
RX
1 2 3 4 5
+
-
COM NO
VALUES
0 = mechanical type (Contact Normally Closed)
1 = resistive type (8,2 Kohm)
VALUES
0 = Total reversal of motion (closing only)
1 = Stop and short reversal of motion
VALUES
from 0 to 10 multiplied by 100 ms
VALUES
from 5 to 20 multiplied by 100 ms
PH1
COM
10
11
12
13
14
15
16
17
18
1 2
NC
+
-
TX
DEFAULT
0
DEFAULT
0
DEFAULT
10 = 1000 ms
DEFAULT
10 = 1000 ms