Sensitivity on obstacle at full speed
• Too high a level of sensitivity could cause an abnormal behavior of the automation depending on the force
that the gear motor needs to move the automation.
• Adjust this parameter according to current regulations.
Set the sensitivity level for the impact sensor to intervene during gate movement.
The impact sensor controls a short reversal of movement to free the obstacle.
PARAMETER
SEn
Sensitivity on obstacle in slowdown
• Too high a level of sensitivity could cause an abnormal behavior of the automation depending on the force
that the gear motor needs to move the automation.
• Adjust this parameter according to current regulations.
Set the sensitivity level to make the impact sensor intervene during the movement of the gate during slowdown.
The impact sensor intervention during slowdown controls a short reversal of the movement to free the obstacle.
PARAMETER
SEL
Normal speed
Set the speed of the motor movement during the movement phase at normal speed.
PARAMETER
SPn
Slowdown speed
Set the speed of the motor movement during the movement phase to slowdown speed.
This value cannot be higher than the set value of "Normal speed".
PARAMETER
SPL
Configuration of the STEP-BY-STEP function
• By setting the CONDOMINIUM functionality you must set an automatic closing time to make the gate close.
Customize the action mode of the STEP-BY-STEP function.
24 - English - Translated from the original language
VALUES
OFF = disabled
from 1 to 100 %
VALUES
OFF = disabled
from 1 to 100 %
VALUES
1 = MIN
2 = LOW
3 = MED
4 = HIGH
5 = MAX
VALUES
from 1 to SPn
NOTE
NOTE
NOTE
DEFAULT
OFF
DEFAULT
OFF
DEFAULT
5 = MAX
DEFAULT
2
6-1622467M - rev. 0 - 07/03/2024