Duration of the deceleration ramp
It takes the gate time to change from normal speed to slowdown speed.
PARAMETER
drA
Mode of intervention PH1 photocell input
During the closing movement the engagement of the connected photocell on the input PH1 always involves the reversal of the
motion and consequent handling up to the position of "OPEN GATE".
Moreover, during the opening movement, the photocell input does not cause any intervention of the control unit.
With this parameter it is possible to customize the behavior of the control unit following the intervention of the photocell, in case the
automation is stopped in the position of "CLOSED GATE".
Value 0: Automation does not start if PH1 input is engaged.
Value 1: The automation moves in opening even if the PH1 input is engaged.
PARAMETER
SPh
Mode of intervention PH2 photocell input
The engagement of the connected photocell on the PH2 input always involves the temporary stop of the movement, until the photo-
cell is released. Once released, automation always moves in the direction of opening.
With this parameter you can customize when this behavior is enabled.
Value 0: Enabled during opening and closing movement.
Value 1: Only enabled during the opening movement.
PARAMETER
Ph2
Auto-test function of the photocell input
• Activation of the self-test function of the photocell input contributes to the achievement of safety stand-
ards throughout the connected control line. Refer to the instruction manual of the connected device for the
degree of safety achieved.
• To properly use this function you need to use terminal number 8 to power the transmitter photocell.
By enabling this function, the control unit performs a functional test of the photocells before each movement. The test, if enabled,
is not performed in case of fast reversals.
PARAMETER
tPh
6-1622467M - rev. 1 - 07/03/2024
VALUES
from 0 to 30 multiplied by 100 ms
VALUES
0 = Check input PH1 from "CLOSED GATE"
1 = Ignore input PH1 from "CLOSED GATE"
VALUES
0 = Enabled in both opening and closing
1 = Enabled only in opening
WARNING
VALUES
OFF = disabilitato
1 = Abilitato per PH1
2 = Abilitato per PH2
3 = Abilitato per PH1 e PH2
NOTE
Translated from the original language - English - 27
DEFAULT
20 = 2000 ms
DEFAULT
1
DEFAULT
0
DEFAULT
OFF