Descargar Imprimir esta página

HR Matic BIOS1 RNS HR Serie Manual De Instalacion Y Uso página 51

Publicidad

Idiomas disponibles

Idiomas disponibles

# TERMINAL
9 - 10
SAFETY EDGE input
During the closing movement, it stops the movement of the automation and performs a reversal until the gate reaches the OPEN
GATE position.
Refer to advanced parameters to configure the behavior of the sensitive edge input and the device type in use.
9
10
Once you have finished the connections, before starting the programming, check that all the red lights of
the safeties are on.
If this does not happen, verify that the un-connected inputs are disabled and that the connected devices are
properly powered and running.
Photocells Series FT / IRIS
Standard connections.
+24V
+24V
GND
TEST
6
7
8
9
10
RX
1 2 3 4 5
+
-
COM NO
NC
6-1622467M - rev. 1 - 07/03/2024
FUNCTION
SAFETY EDGE
PH1
11
12
13
14
15
16
17
1 2
+
-
Connect mechanical (NC) or resistive (8.2
Kohm) sensitive edges.
Signal LED Normally On.
SAFETY EDGE
NOTE
COM
18
TX
DESCRIPTION
Translated from the original language - English - 13