5. ERROR MESSAGES
Message reporting persists as long as the event persists or until the DOWN key is pressed or a handling
command is executed.
DISPLAY
Limit switch error: Opening and closing limit
ELS
switches occupied simultaneously or locked.
Movement stopped by the impact sensor. Effort too
EFO
high to allow movement of the gate.
Movement stopped by the intervention of the
EEd
sensitive edge (EDGE input).
EPH
Photocell test error. The photocell test failed.
Eth
Thermal intervention to safeguard the board.
Electric motor error not connected or in thermal
EMS
protection.
Error in remote control memory. Memory not
EME
installed or not recognized.
Full remote control memory. It is no longer possible
FUL
to learn more remote controls.
Error in memory query during learning functions,
Err
position display or transmitter deletion.
36 - English - Translated from the original language
NOTE
DESCRIPTION
SOLUTION
• Check that the limit switch is not blocked.
• Check electrical connections and limit switch
integrity.
• Check the integrity of the fuses.
• Check the integrity and good condition of the
entire gate and automation.
• Remove any dirt or foreign matter that may
hinder movement.
• Adjust the sensitivity parameters of the impact
sensor.
• EDGE input activated.
• Verify that the device connected to the EDGE
input is working properly and configured.
• Check the test connection of the photocells and
the correct setting of the TPH parameter.
• Verify that the photocells are working and
replace them.
• Wait for the automation to cool down before
performing further handling.
• Please ensure that you do not exceed the use
threshold indicated in this user manual.
• Check the connections to the electric motor.
• Wait for the electric motor to cool and make sure
that you do not exceed the indicated operating
threshold.
• Remove and insert the remote control memory
again.
• Perform the remote control memory reset proce-
dure (TRF parameter).
• Replace the remote control memory with a new
one.
• Clear some remote controls.
• Replace the remote control memory with a new
one.
• Incorrect selected memory location.
• Replace the remote control memory with a new
one.
6-1622467M - rev. 0 - 07/03/2024