4.2 - DISPLAY MODE
The display available in the control unit allows you to view a lot of information such as the status of the automation, the number of
movements performed, anomalies detected, etc.
There are 4 types of views available.
To switch from one type to another press the DOWN button.
VIEW 1: STANDARD
In this mode you can view the automation status and error messages.
Refer to the next chapter for more information about the message type.
VIEW 2: NUMBER OF MOVEMENTS CARRIED OUT
In this mode you can see the number of cycles (opening and closing) performed by the automation.
The control panel will alternate two values: the first, without dots, indicates the thousands; the second, with dots, indicates the units.
For example:
001 = 1 thousand
02.0. = 20 units
Total = 1020 cycles completed.
VIEW 3: CURRENT ABSORBED BY THE MOTOR (rms)
In this mode you can see the current absorbed by the motor (mA).
VIEW 4: CURRENT ABSORBED BY THE MOTOR (peak)
In this mode you can see the current absorbed by the motor (mA).
view 4
16 - English - Translated from the original language
DOWN
view 1
DOWN
view 3
DOWN
view 2
DOWN
6-1622467M - rev. 0 - 07/03/2024