4.6 - MENU OF BASIC FUNCTIONS
To access the basic function menu, press and hold the MENU button for 1 to 3 seconds.
Use the UP and DOWN buttons to scroll through the available features.
While displaying a function, the control unit will alternate the display of the item to the value set in it.
To change the value of the parameter you are viewing proceed as follows:
•
Press and hold the menu key for at least 3 seconds, the currently set value flashes.
•
Use the UP and DOWN keys to select the desired value.
•
Confirm the value by holding down the MENU key for at least 3 seconds.
To exit quickly press the MENU button.
Automatic Closing
• If used together with the parameter "Automatic Closing after Transit", the latter is not considered.
• This parameter does not affect if the gate reaches the position of "PARTIAL OPENING".
Set an automatic closing time.
Once reached the position of "GATE OPEN" the control unit starts the countdown by displaying on the screen "-tC" (the symbol "-"
is replaced by a number in the last 10 seconds of the countdown).
In case the photocell input is active the countdown is restored and remains locked until the contact is restored.
PARAMETER
tCL
Automatic Closing after Transit
• When used together with the "Automatic Closing" parameter, the "Automatic Closing after Transit" param-
eter is not considered.
• This parameter does not affect if the gate reaches the position of "PARTIAL OPENING".
Set an automatic closing time after the passage.
Once reached the position of "GATE OPEN" the control unit is waiting and displays on screen "-tt".
The countdown starts only after the engagement and subsequent disengagement of the PH1 photocell input.
The symbol "-" is replaced by a number in the last 10 seconds of the countdown.
In case the photocell input is active the countdown is restored and remains locked until contact is restored.
PARAMETER
ttr
6-1622467M - rev. 1 - 07/03/2024
PARAMETER LIST
VALUES
OFF = disabled
from 1 to 900 seconds
VALUES
OFF = disabled
from 1 to 30 seconds
NOTE
NOTE
Translated from the original language - English - 23
DEFAULT
OFF
DEFAULT
OFF