STANDARD PROCEDURE FOR LEARNING
With standard learning, the control unit performs all the procedure and the calculation of slowdowns, which will be regulated with
the same amplitude both in opening and closing ( see basic parameter " LsI").
• Check that during the first movement the display displays "LOP" and the gate moves in the OPENING
DIRECTION.
If necessary, press the DOWN button and then the SS button to reverse the movement.
• In order for the automation and all the safety devices installed to function correctly, it is
necessary to verify the correct direction of the automation movement.
• If the procedure starts while the limit switches are active, or if a safety device is involved during movement,
the procedure is stopped and the words " L--" appear on the display.
Carry out the appropriate checks and press the SS button to resume learning from step 3.
Unlock the transmission of the gear motor and carry the gate by hand
1.
halfway.
Then insert the motor transmission again.
Press the UP button and the MENU button simultaneously for at least
5 seconds until the display shows " LOP ".
2.
At this stage the gear motor moves in search of the opening limit
switch.
Verify that the automation moves in the opening direction.
Once the opening limit switch has been reached, the automation
3.
automatically moves to the closing limit switch.
At this stage the display shows " LCL ".
Once the closing limit switch is reached, the automation automatically
4.
moves into the opening, until the opening limit switch is reached.
At this stage the display shows " LOP ".
Once the opening limit switch has been reached, the automation
5.
moves into closing at full speed at the end of which it applies the
calculated slowdown area.
6.
After the procedure the control unit displays "Ldone"