Normal: ("OPEN" - "STOP" - "CLOSE" - "STOP" - ...)
Classic operation of the STEP-BY-STEP mode. During handling, a STEP-BY-STEP control involves stopping the automation.
Alternate STOP: ("OPEN" - "STOP" - "CLOSE" - ...)
Alternating operation with possibility of STOP during the opening movement. During the closing movement performs a reversal of
motion.
Alternate: ("OPEN" - "CLOSE" - ...)
Performs only the opening or closing command of the automation. While moving, a STEP-BY-STEP command reverses the direction
of travel.
Condominium (Timer): ("OPEN" - ...)
The STEP-BY-STEP control allows only a complete opening of the automation. If the command persists with the automation in the
GATE OPEN position, you will wait for the release before starting the countdown to the automatic closing. Each press of the STEP-
BY-STEP control restores the countdown.
Condominium with immediate closure: ("OPEN" - ...)
If the automation is not in the OPEN GATE position, the STEP-BY-STEP control allows a complete opening of the automation. When
the automation is in the OPEN GATE position, a STEP-BY-STEP command immediately closes the automation, resetting the automatic
closing timer if present.
PARAMETER
SbS
Behavior after Black-out
Allows to automatically execute a closing command to reset the main supply voltage, following a Black-out. This movement is always
carried out at slow speed, until the "CLOSED GATE" position is reached.
PARAMETER
blt
Width of the slowdown area
Adjusts the width of the opening and closing slowdown area as a percentage of the total stroke length.
With the value "P" you can set custom areas during the learning of the races (see paragraph LEARNING WITH PERSONALIZED
SLOWDOWNS).
PARAMETER
LSi
Anti-skid function (EXTRA TIME)
It allows you to add extra working time compared to that stored during the course learning procedure, so as to ensure the complete
closure of the automation even if the working time learned is not sufficient to get to the position of "CLOSED GATE".
PARAMETER
ASL
6-1622467M - rev. 1 - 07/03/2024
VALUES
0 = Normal
1 = Alternate STOP
2 = Alternate
3 = Condominium (timer)
4 = Condominium with immediate closure
VALUES
OFF = disabled
ON = Automatically execute a "CLOSE" command
VALUES
OFF = disabled
1 to 100 % of total length
P = personalised areas
VALUES
OFF = disabled
from 1 to 300 seconds
DEFAULT
0 = Normal
DEFAULT
OFF
DEFAULT
15 %
DEFAULT
15 seconds