GENERAL INFORMATION
The following instruction is only to demonstrate the correct set-up of the joimax
recommendation for the surgical use of the instrument.
PRODUCT DESCRIPTION
The joimax
Vaporflex
Handle is an electrosurgical instrument for use in minimally invasive procedures. joimax
®
®
different bipolar probes varying in length, diameter and tip configuration. Various shaft lengths and/or shaft versions are
available depending on the procedure and length of the probe.
The probes are available from joimax
nents, available either in a set or individually. These are non-sterile and must be reprocessed and sterilized before the first
use according to the reprocessing instructions.
The Vaporflex
instrument comprises: handle, shaft and RF/HF-cable. The device must be fitted with a suitable disposable
®
bipolar probe.
The joimax
Vaporflex
instrument is designed and intended for use only with electrosurgical RF/HF generators that have been
®
®
tested at least to IEC 60601-1 3rd ed., IEC 60601-2-2, IEC 60601-1-2 (i.e. elliquence
Vapor, joimax
Endovapor
2, joimax
®
®
The joimax
Vaporflex
Handle is a Class I medical device in accordance with MDD 93/42/EEC.
®
®
INDICATIONS OF USE
The joimax
Vaporflex
and Legato
®
®
or minimal invasive surgical procedures when used in conjunction with a compatible RF/HF generator.
The joimax
bipolar electrosurgical instruments have not been shown to be effective for tubal sterilization or tubal coagu-
®
lation for sterilization procedures and should not be used for these procedures.
Model JVP32024 Vaporflex
®
Model JVP27525S Vaporflex
Model JVP25024 Vaporflex
®
Model JBPP27020 Legato
®
Model JBPH352505 Legato
®
Model JVH32030 Vaporflex
®
Model JVHS32030 Vaporflex
Model JVHS27527S Vaporflex
Model JVHS25030 Vaporflex
Model JVUH10010 Vaporflex
Model JVC35010 Vaporflex
®
Model JVC35020 Vaporflex
®
Model JVHP10023 Vaporflex
CONTRAINDICATIONS
• Do not use on patients for whom an electrosurgical procedure is contraindicated for any reason.
• Not for use in cardiac interventions.
• Do not use on patients with heart pacemakers or other electronic device implants without first consulting a
qualified professional.
1 Instruments tested in combinations with electrosurgical generator elliquence
as individual sterile packaging. The Vaporflex
®
Endovapor
)
. Refer to the RF/HF generators documentation to ensure compatibility.
®
®
1
bipolar electrosurgical instruments are used for coagulation of soft tissue during open
®
Probe, Bipolar, Ball Tip 320
Probe, Bipolar, Ball Tip 275
®
Probe, Bipolar, Ball Tip 250
Probe, Bipolar, Ball Tip 270
Handpiece, Bipolar, for SurgiMax
Handle and Shaft, 320
Shaft 320
®
Irrigation Shaft 275
®
Shaft 250
®
Handle
®
Cable, for SurgiMax
/ Endovapor
®
Cable, for Endovapor
2
®
Spare Sealing Rings
®
Vaporflex
®
Handle comprises different compo-
®
SurgiMax
®
/ Endovapor
/ Endovapor
®
®
®
SurgiMax
in modes "Bipolar Hemo" and "Bipolar Turbo"
®
®
Handle and does not give any
®
offers
®
, SurgiMax
Plus, SurgiMax
®
®
2
®
®
3