Cleave Limit
Loss Limit
Arc power
Arc time
Cleaning Arc
Rearc Time
Proof Test
B. For splice parameter file which is set to Normal or
Special [Mode], if first press
can switch between 7 screens; Press
return to the previous operation interface.
<1> The first screen in the "editing splice parameter files"
menu:
©Copyright Abacanto Digital SA.
An error message is displayed if the cleave angle of either the
left or right fiber ends exceed the selected threshold (cleave
limit).
An error message is displayed if the estimated splice loss
exceeds the selected threshold (loss limit).
Under Auto/Calibrate fusion model, Arc power is fixed at
80bits.
Under Auto/Calibrate fusion model, Arc time is fixed at
1500ms and cann't amended.
A cleaning arc burns out micro dust on the surface of the fiber
with an arc discharge for a short period of time. The duration
of the cleaning arc can be changed by this parameter.
Under certain conditions, it shall be mended fusion loss
through rearc time again. The duration of the rearc time can be
changed by this parameter.
If [Proof Test] is set to "ON", a proof-test is performed
automatically.
, then the menu of "editing splice parameter files"
Manual de usuario AD300
AD Instruments
and then press
one by one to
118